2
Product Description
Logalux PL750/2 S - Changes may be made following technical improvements!
7
2.7
Technical Specifications
Tank model
PL750/2 S
Tank volume total
gal
198
l
750
Tank volume DHW
gal
79
l
300
Tank volume Buffer
gal
119
l
450
Diameter D
inch
39
mm
1000
Diameter D (without insulation)
inch
31.5
mm
800
Height H
inch
76
mm
1920
AW
NPT ¾ "
VS
1
NPT ¾ "
RS
1
NPT ¾ "
VS
2
-VS
5
NPT 1¼ "
RS
2
-RS
5
NPT 1¼ "
EL
NPT 1¼ "
EL
1
NPT ¾ "
EK
NPT 1 "
EZ
NPT ¾ "
Dry weight
1)
1) Dry weight, incl. packaging material.
lb.
573
kg
260
Maximum Operating Values:
Temperature Buffer water /solar
loop
°F
230
°C
110
DHW temperature
°F
203
°C
95
Operating pressure solar loop
psi
116
bar
8
Operating pressure DHW
psi
147
2)
2) In the Commonwealth of Massachusetts the operating pressure
is limited to 100 psi. Install a 100 psi relief valve.
bar
10
3)
3) Every installation requires the use of a thermal expansion tank
and pressure/temperature relief valve in the heating system and
solar system.
Operating pressure buffer water
psi
43.5
bar
3
Tab. 1
Technical Specifications