4
Tank Assembly
Logalux PL750/2 S - Changes may be made following technical improvements!
14
4.2
Installation of the Insulation
V
Push the insulation with holes [9] for the tank feet
under the solar combi-tank.
V
Place the two insulation jacket [1] sections on the front
of the tank.
V
Connect the top section of the cover strip [3].
V
Fold the insulation jacket section to the back of the tank
and connect the back cover strip
V
Install the short cover strips [2] of the insulation jacket
to the tank.
V
Force the insulation by moving the short cover strips at
the back to the next possible step.
V
Install the top insulation pieces [4] and [5], so that the
thicker top insulation [5] will end up at the same level
like the tank shell insulation [1].
V
Install the insulation piece [6] for the tank connections.
V
Install the top cover [7] so that there are no exposed
gaps in the insulation jacket.
V
Seal the top cover with a strap and 4 coiled spring pins
[8].
Fig. 12 Installation of the PL750/2 S insulation jacket
1
Insulation
2
Short Cover strip
3
Front cover strip
4
Top insulation (2 inch/50 mm)
5
Top insulation (4 inch/100 mm)
6
Insulation clean-out cover
7
Top tank cover
8
Strap with spring pins
9
Bottom insulation
On the PL750/2S tank we recommend you
install the insulation jacket only after the tank
has been tested for leaks.
The ideal temperature to install the insulation
jacket is 60 °F (15 °C). Slight tapping on the
jacket in the direction of the seal should help
with the ease-of-installation.
6 720 615 217-19.1RS
7
8
9
6
3
2
1
5
4