Operation
WINDINGFEEDER
- 3-17 -
P4 Programming Level
LFA m/min
Î
ADVANCED
Î
MENU P4
The P4 programming level allows you to select the various device operating
modes:
1)
Yarn feeding motor rotation direction (clockwise or counter clockwise);
2)
Size in grams of TS44.. tension sensor used (either 100 g. or 1,000 g.);
3)
Communication baud rate over the serial interface;
4)
Application on which the device will be used;
5)
Yarn type: either normal or elastic;
6)
Language used to display menus and messages;
7)
Polarity of Input and Stop signals (Normally Open or Normally Closed
contact).
8)
Automatic detection of the optional intelligent accessory.
to select the P4 level.
to continue.
P4.1
MOTOR D
This function allows you to choose the rotation direction of yarn feeding motor
(CW = Clockwise, CCW = Counter-Clockwise)
.
To move from CW value
(Clockwise)
to CCW value
(Counter-Clockwise)
or vice
versa, press and hold down for 3 seconds the
button.
to move to next parameter.
P4.2
SENSOR TYPE
Choose the size in grams of the TS44.. tension sensor used: allowed values 101 or
102
.
(101 if you are using the TS44/100DRW sensor or 102 if you are using the
TS44/1000ERW sensor)
Use the
or
buttons to toggle from 101 to 102 and vice versa.
to confirm.
Содержание WINDINGFEEDER
Страница 1: ...WINDINGFEEDER YARN CONTROL SYSTEM Operating Manual ENGLISH Rev 2 0 March 2011 ...
Страница 4: ...Table of Contents ii WINDINGFEEDER Page intentionally left blank ...
Страница 13: ...Overview WEENDINGFEEDER 1 7 PC Link KTF Examples of WINDINGFEEDER device operation parameters programming ...
Страница 19: ...Technical Data and Installation WINDINGFEEDER 2 5 WINDINGFEEDER overall dimensions in mm ...
Страница 22: ...Technical Data and Installation 2 8 WINDINGFEEDER Page intentionally left blank ...
Страница 42: ...Operation 3 20 WINDINGFEEDER Page intentionally left blank ...