WINDINGFEEDER Troubleshooting and Maintenance
WINDINGFEEDER
- 4.3 -
Anomalie
Cause
Rimedi
TM
displayed on
WINDINGFEEDER
display
1) La temperatura del motore è
superiore a quella massima
prevista.
1) Check the usage conditions of the systems.
If you cannot locate the cause of failure,
please contact your BTSR reseller (it could
be necessary to send the device to the
BTSR repair centre).
The machine is not
stopped by
WINDINGFEEDER
device in case of yarn
breakage
1) The third parameter of the
P1
programming level has been
de-activated (OFF)
2) Wiring problem.
1) Confirm the correct programming of
WINDINGFEEDER parameters. Check the
correct connection of P1-P2 inputs.
2) If the red LEDs on WINDINGFEEDER device
turn on when the yarn breakage occurs, than
check for correct machine connections.
To check the correct operation of the
WINDINGFEEDER
STOP output press the
"Control
"
button and confirm the
lighting of red LEDs; if this does not occur
please contact your BTSR reseller (it could
be necessary to send the device to the
BTSR repair centre).
The
WINDINGFEEDER
device does not
communicate with
SMART MATRIX
FEEDER terminal
1) The identification code of
WINDINGFEEDER device is
not correct
2) Failure on SMART MATRIX
FEEDER terminal
3) Wiring problem
1) Check that the parameter corresponding to the
identification number
(parameter
P3.4
)
is correct;
if necessary carry out the numbering procedure
using the SMART MATRIX FEEDER terminal or
set directly the identification code on
WINDINGFEEDER device
(parameter
P3.4
)
.
2) Check the correct operation of SMART MATRIX
FEEDER terminal using the numbering
procedure described in the SMART MATRIX
FEEDER manual.
3) Check the overall device wiring.
ASC1010 COM-ERROR
displayed on
WINDINGFEEDER
display
1) Missing communication
between main DSP and
loading cell DSP.
1) Reset the alarm; if the problem persists, contact
your BTSR reseller.
Содержание WINDINGFEEDER
Страница 1: ...WINDINGFEEDER YARN CONTROL SYSTEM Operating Manual ENGLISH Rev 2 0 March 2011 ...
Страница 4: ...Table of Contents ii WINDINGFEEDER Page intentionally left blank ...
Страница 13: ...Overview WEENDINGFEEDER 1 7 PC Link KTF Examples of WINDINGFEEDER device operation parameters programming ...
Страница 19: ...Technical Data and Installation WINDINGFEEDER 2 5 WINDINGFEEDER overall dimensions in mm ...
Страница 22: ...Technical Data and Installation 2 8 WINDINGFEEDER Page intentionally left blank ...
Страница 42: ...Operation 3 20 WINDINGFEEDER Page intentionally left blank ...