Operation
WINDINGFEEDER
- 3-15 -
P3 Programming Level
LFA m/min
Î
ADVANCED
Î
MENU P3
The P3 programming level allows you to setup 4 functionality:
1)
Offset reading/execution and Auto Offset enabling;
2)
Device operation mode;
3)
Access code to programmable function;
4)
WEENDINGFEEDER identification code.
to select the P3 level.
to continue.
P3.1
OFFSET
By “offset” we means the calibration of the TS44.. sensor’s mechanical clamping
position.
It clears possible measurement errors due to the different clamping position of the
device on textile machine. The displayed indication is the
actual
OFFSET
value
resulting from the clamping position of the device.
While lifting the yarn above the loading cell, press
to check whether the
stored
OFFSET
value corresponds to the
actual
OFFSET
value. If the two values are
different, press briefly
to align them.
You may either enable or disable the Automatic Offset function keeping
pressed for 3 seconds. If the function is disabled, then
AUTO
does not appear on the
display.
If it is enabled, then at every machine stop the device loosens the yarn until this is
completely relaxed and it carries out an automatic correction of the Offset value.
You are recommended to enable the Auto Offset function only for low tensions
(lower than 1.0 grams).
Auto-Calibration of the Loading Cell
Holding down
for 3 seconds you may activate the loading cell Auto-
Calibration function which brings back the Offset value to 5.0 grams
(factory
calibration value of Windingfeeder devices)
.
During the auto-calibration process, an “
OFFSET INT
-
CALI
” message is temporarily
shown on the display.
to select the next parameter.
The auto-calibration function can be carried out only when using theTS44..
sensor (not available on TS4.. sensor):
Содержание WINDINGFEEDER
Страница 1: ...WINDINGFEEDER YARN CONTROL SYSTEM Operating Manual ENGLISH Rev 2 0 March 2011 ...
Страница 4: ...Table of Contents ii WINDINGFEEDER Page intentionally left blank ...
Страница 13: ...Overview WEENDINGFEEDER 1 7 PC Link KTF Examples of WINDINGFEEDER device operation parameters programming ...
Страница 19: ...Technical Data and Installation WINDINGFEEDER 2 5 WINDINGFEEDER overall dimensions in mm ...
Страница 22: ...Technical Data and Installation 2 8 WINDINGFEEDER Page intentionally left blank ...
Страница 42: ...Operation 3 20 WINDINGFEEDER Page intentionally left blank ...