Electrical System – 5000 LWE 180/200 LPE 200
Error codes
Order number
Date
Valid from serial number
T-code
225553-040
2005-05-11
723984-
660, 661, 662, 497
© BT Europe AB
Service Guide
LWE180, LWE200, LPE200, LPE240
9- 21
Code
C42
Description
Warning of high battery voltage
Possible error
cause
Battery voltage > 33 volt.
Energy return feed to battery during motor braking
with a fully-charged battery.
Action
1.
The fault disappears after a few lifts, once the
battery has been run down slightly.
2.
Check the cabling, the battery contact and the
contact points on main contactor K10.
Code
C43
Description
The travel regulator shuts off due to excess or
subnormal temperature.
Possible error
cause
Too intensive operation or ambient temperature
too cold.
Error in the travel regulator.
Temperature levels below -25
o
C or above +85
o
C
reduce running speed.
Action
1.
Check that the M12 fan is functioning.
(Applies to P 24)
2.
Check that the travel regulator is installed with
good contact with the chassis.