Hydraulic, pneumatic – 6000 LPE 240
Cleaning the filter
T-code
Valid from serial number
Date
Order number
660, 661, 662, 497
723984-
2005-05-11
225553-040
12.3 Cleaning the filter
•
Dismantle the hydraulic unit from the machine.
•
Empty the oil from the tank.
•
Loosen and remove the hose clip (1).
•
Loosen and remove the two tank holders (2).
•
Loosen the suction filter (5) and the return filter (3).
•
Clean the filter in an environment friendly cleaning agent.
Assemble in the reverse order.
2
1
3
4
5