Electrical systems – 5000 LPE 240
Hour meter
Order number
Date
Valid from serial number
T-code
225553-040
2005-05-11
723984-
660, 661, 662, 497
© BT Europe AB
Service Guide
LWE180, LWE200, LPE200, LPE240
10- 13
10.4 Hour meter
•
Press S18 and turn S17 to on at the same time.
•
Press S18 until you read the H= hour meters.
•
You have now choosen H=hourmeters the symbol “B” will be high-
lighted.
•
You can now choose type of hourmeter by pressing L1.
1(A)= Key time.
2(b)= Drive motor time.
3(c)= Pump motor time.
4(d)= Activity time.
5(s)= Time left to make service.
10.5 Error codes
•
Press and hold S18 while turning S17 to “ON” position.
•
Press and hold S18 until E = error codes is displayed.
•
When E is selected, the “E” symbol will light up as an indication of
what is shown in the display.
•
The 50 most recent error codes are stored. The latest error is dis-
played first. The display shows the error code first, followed by the
time when the error occurred.
•
The error codes are divided into two groups, C = caution and E = error.
•
C codes are not stored. They are only cautions and remain lit in the
display as long as the fault remains.
•
If there is only one error registered in the memory, the other empty
entry lines appear as follows: Error: E - - - and time: - - - - .
Code
C3
Description
TLS: Shock sensors registered values outside
the limits
Possible error
cause
A shock sensor has reported values that exceed
the truck’s tolerance values.
Driving may be too hard
Check that the shock sensor’s limit values are
correctly set.
Check that the shock sensor is correctly posi-
tioned./The brake engages and stops the truck.
The TLS reset command activates the truck
A
B
C
D
E