9- 32
Service Guide
LWE180, LWE200, LPE200, LPE240
© BT Europe AB
Electrical System – 5000 LWE 180/200 LPE 200
Parameters
T-code
Valid from serial number
Date
Order number
660, 661, 662, 497
723984-
2005-05-11
225553-040
9.6.3 Service parameters
•
Connect the CAN key to X41.
•
Press and hold S18 while turning S17 to “ON” position.
•
Press and hold S18 until P = parameters is displayed.
•
You have now selected P = parameters and the symbol “C” is lit as
an indication of what is now shown in the display.
•
Press L1 up or down and scroll to the parameter you want to change
or view.
•
Press S18 once to access the parameter.
•
Press L1 up or down to specify the parameter value.
•
Press S18 once to confirm the change.
•
Turn S17 to the off position.
You have now changed the parameter and the new setting will come
into force the next time you start the machine.
NOTE:
Truck handling
When you change specific truck parameters, the truck’s driving char-
acteristics are also changed.
Do not change any parameters unless you really know what you are
doing.
Parameter
Description
Unit
Min.
Max.
Step
Std.
Description
10
PIN-code
0
9999
1
1
Facility for specifying up to 10
PIN codes (10 different drivers).
14
Crawling
speed
-10
10
1
0
The amount of power the mon-
itor should emit when you
reach the first speed sensor
can be specified here.
-10: low speed for the first
speed sensor.
10: high speed for the first
speed sensor
15
Non-config-
urable option
0 to 9
See “Option parameters” on page 34, Servicemanual
16
Configurable
option #1
See “Option parameters” on page 34, Servicemanual
17
Configurable
option #2
18
Configurable
option #3
19
Configurable
option #4
20
Hour meter
option
1
5
1
2
Select hour meter.
21
Battery size
1
20
1
5
Selection of battery size.
A
B
C
D
E