87 / 150
Manual PRO50-150 V.2
4.1.5.3- Super chlorination
Select this option if you require super-chlorination of your swimming pool,
bearing in mind the following:
-
If the equipment is working in semi-automatic mode
(with the NTC
PROBE KIT )
, the equipment will calculate the time necessary
depending on the volume and Temperature. The filtering time to perform
super-chlorination will be displayed on the screen.
-
Without a Temperature probe, super-chlorination will be carried out for
24 hours. If filtration is stopped, super-chlorination is suspended.
4.1.5.4- Calibration of the free chlorine probe
If you have a free chlorine probe, a menu will appear for you to calibrate it.
Once the reading has stabilized and the chlorine measurement has been taken
with
DPD1
,
adjust the
PPM
value provided by the DPD1 measurement.
4.1.6- pH menu
With this menu, you can adjust the parameters related to the pH adjustment of
your swimming pool. It only appears in PRO series equipment.
4.1.6.1- Main screen
The reading of the pH probe can be seen in the 3rd line of the main screen.
pH adjustment does not start up until 5 minutes after the equipment
has been switched on.