92 / 150
Manual PRO50-150 V.2
Incrustations or objects in
the electrolysis cell causing
excess current.
Clean the cell.
"CLEANING"
The chlorinator is in the
self-cleaning process. The
process lasts 5 minutes
None.
"TEMPERATURE".
The ambient temperature is
>40º
Try and place the equipment in
another position where it is not
over 40º or perform forced
ventilation.
Leave
the
equipment to rest for a few
minutes.
Consult section number
4. Installation
The
radiator
fins
are
obstructed or are not in a
vertical position.
Place the equipment so that air
is circulated for correct cooling.
4.2.1.1- Additional warning messages
ORP or PPM value is
flashing
The
redox
or
free
chlorine
probe
are
balanced in automatic
mode. When the probe
is balanced, the value
remains set.
None.
pH value is flashing
The
pH
probe
is
balancing. When the
probe is balanced, the
value remains set.
None.
Value
---o
(Water
temperature) is flashing
The value of the water
temperature is under
15º.
Consider the use of a
winter
hibernator
product.
Filter time
The
equipment
has
switched off before the
time
set
in
semi-
automatic
Restart the filtering cycle