51 / 150 

Manual PRO50-150 V.2 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

CHLORINATOR INFORMATION

 

 
 
 

 

PLEASE NOTE IN THE FOLLOWING CARD THE REGISTRATION DATA OF 

THE EQUIPMENT YOU HAVE PURCHASED, WHICH ARE FOUND ON THE SIDE

 

LABEL.

 

 

THESE DATA WILL BE OF USE IF YOU WISH TO MAKE ANY ENQUIRY TO

 

YOUR SUPPLIER

 

MODEL……………………………………………… 

REF.  ………………………………………………….. 

VOLTAGE……………………………………………..

 

SERIAL NUMBER.…………………………………………

 

Содержание BS POOL PRO Series

Страница 1: ...1 150 Manual PRO50 150 V 2 CLORADOR SALINO SALT WATER CHLORINATOR SALZWASSER CHLORINATOR PRO50 PRO70 PRO100 PRO150 MANUAL DE USUARIO USER MANUAL GEBRAUCHSANLEITUNG...

Страница 2: ...FORMATION PLEASE NOTE IN THE FOLLOWING CARD THE REGISTRATION DATA OF THE EQUIPMENT YOU HAVE PURCHASED WHICH ARE FOUND ON THE SIDE LABEL THESE DATA WILL BE OF USE IF YOU WISH TO MAKE ANY ENQUIRY TO YOU...

Страница 3: ...2 7 Conductivity probe kit 72 3 3 Electrical wiring diagram 74 3 3 1 PRO50 70 series equipment 74 3 3 2 PRO100 150 series equipment 75 3 3 3 Advanced Functions 76 4 START UP AND ADJUSTMENTS 4 1 PRO s...

Страница 4: ...Free chlorine hypochlorous acid HClO is produced which is a strong bactericide Results are similar to the chemical products that are normally added Saline electrolysis is a reversible process meaning...

Страница 5: ...atic switch off owing to lack of water flow Automatic voltage adjustment depending on the concentration of salt and the temperature keeping continuous chlorine production Automatic cleaning cycle of e...

Страница 6: ...chlorinator works correctly a small amount of salt should be added and the pH level should be suitable The recommended salt and pH levels are the following Salt Concentration g l Ph PRO50 70 4 to 6 7...

Страница 7: ...g in the water circuit 2 2 Chemical balance of the water The effectiveness of chlorination and the quality of water for healthy bathing depends largely on the pH of the water Therefore it should be ch...

Страница 8: ...lectrolysis circuit Always try and ensure that the filter is between both and that there is at least half a metre of water flow between the probe and the chlorination cell The REDOX probe should be in...

Страница 9: ...al Panel 4 Bypass 5 Flow Switch optional 6 Conductivity probe optional 7 Temperature probe optional 8 pH probe included in AUTO kit optional 9 Redox probe included in ADVANCED kit optional 10 Ground k...

Страница 10: ...ss 5 Flow Switch optional 6 Conductivity probe optional 7 Temperature probe optional 8 pH probe included in AUTO kit optional 9 Redox probe included in ADVANCED kit optional 10 Ground kit optional 11...

Страница 11: ...trolysis cells RP150 RP100 Connecting the cells to the unit Once the cells are installed connect the cables to each side of the cell using the provided nuts and bolts Verify that the cable terminals a...

Страница 12: ...PRO Equipment 2 Suction Tube flexible 3 Injection Tube rigid 4 Suction filter place vertically on the bottom of the acid container 5 pH Probe 6 Probe Holder 7 Flange 8 Injector place with the arrow fa...

Страница 13: ...ted after the electrolysis cell 2 Place the flange 7 in the pipe as indicated in the hydraulic connection diagram The flange 7 corresponds to the PH probe and should be connected after the electrolysi...

Страница 14: ...ust the required level and the equipment automatically maintains the level of disinfection by adjusting the production of chlorine to the real needs of the swimming pool The screen shows the Redox lev...

Страница 15: ...gh a membrane This ppm measure has a low dependency of pH and isocyanuric acid and it can be also installed in sea water swimming pools this option to be asked to BSV Electronic Please follow carefull...

Страница 16: ...nce period Water test Minimum once a week Header membrane change Once a year Electrolyte change Every 3 6 months depending on the quality of the water 3 2 5 3 Installation Please carefully follow the...

Страница 17: ...an alternative the inlet can be connecter before the filter but then it is strictly necessary to install a specific cartridge filter to avoid the probe contamination 3 2 5 3 2 Probe set up Before inst...

Страница 18: ...ctly otherwise the header membrane could be damaged and will be out of warranty 4 Screw the header cap to the body of the probe The excess of electrolyte will leak out across the small hole and the up...

Страница 19: ...input Once the connection is done screw the cap and the cable gland Connect the cable to the unit as follows o White cable Input 11 o Dark cable Input 10 o A cable bridge must be done between inputs...

Страница 20: ...s switched on for the first time the stabilization time could take longer than usual In any case it is recommendable to wait for at least 3 hours before making a first calibration 4 Calibration Wait u...

Страница 21: ...real value obtained by means of DPD 1 test d Return to the main screen The current CL value will match with the value obtained from DPD 1 test 3 2 5 3 5 Probe maintenance Please carefully read the fo...

Страница 22: ...e old electrolyte Handle it carefully to avoid damaging the membrane 3 Clean the Sharp point of the probe using the supplied abrasive paper Please do it carefully without an excessive pressure 4 Caref...

Страница 23: ...chlorination Systems and it will allow to know the salt concentration in the water and also the electrolysis cell condition This sensor is been designed to work with BSPOOL Systems exclusively In orde...

Страница 24: ...o any warning related with the lack or too much salt conditions Lack of salt Measure 4g l Too much salt Measure 8g l 3 2 7 3 Calibration and maintenance The conductivity sensor comes already calibrate...

Страница 25: ...elay FILTER Start Stop input J4 Cell connection J8 1 Acid level sensor PH 8 Temperature probe 2 Acid level sensor PH 9 ORP 3 Cover 10 ORP 4 Cover 11 12V for free chlorine 5 Flow sensor white cable 12...

Страница 26: ...Stop input J27 Cell connection J4 1 Acid level sensor PH 8 Temperature probe 2 Acid level sensor PH 9 ORP 3 Cover 10 ORP 4 Cover 11 12V for free chlorine 5 Flow sensor cable 1 12 Conductivity 6 12V f...

Страница 27: ...hat when the filtering pump starts up it will instruct the chlorinator to start up When the pump stops the screen of the chlorinator will display the message stop To activate this mode remove jumper L...

Страница 28: ...iary relay incorporated in the PRO series equipment Lighting of your swimming pool can be programmed to switch on and off following this diagram Attention Never exceed 12A when using the auxiliary rel...

Страница 29: ...3 Filtering control through the auxiliary relay The filtering pump can be controlled through the auxiliary relay following this diagram Please remember that the equipment should be configured in start...

Страница 30: ...ng table shows how to organize the configuration menu of the equipment Chlorinating Menu Chlorination menu Main menu of production Max ORP CL Configuration Super chlorination Chlorination Calibration...

Страница 31: ...he water temperature consecutively If you do not have a temperature probe will appear The second line displays the oxidation reduction potential called RedOx or ORP Oxidation Reduction Potential or pp...

Страница 32: ...ess the configuration menu you need to confirm the operation by selecting S through the arrow and pressing OK 4 1 4 Configuration In the configuration menu you can select the configuration parameters...

Страница 33: ...s you to automatically adjust the level of chlorine in your swimming pool Based on the adjusted set value in the chlorine menu the equipment will stop when it reaches this value and start up again aut...

Страница 34: ...an optimum level of chlorine in the water the equipment will display a warning message 4 1 4 5 Location of the swimming pool Attention This work mode only affects the semi automatic operation mode Th...

Страница 35: ...e is water flow in the piping If it detects that there is no flow the production will stop and an alarm will sound accompanied by a red warning LED Once the flow has been reestablished the equipment w...

Страница 36: ...works continuously for more than 2 hours This could occur for the following reasons The acid tank is empty and therefore pH corrector is not being injected into the swimming pool The pH probe is dirty...

Страница 37: ...hat are not used frequently 650 mV is a sufficient value 700 mV is the suitable value for the majority of swimming pools Press OK to confirm the adjustment However the best way to adjust the optimal O...

Страница 38: ...for 24 hours If filtration is stopped super chlorination is suspended 4 1 5 4 Calibration of the free chlorine probe If you have a free chlorine probe a menu will appear for you to calibrate it Once...

Страница 39: ...irm with OK 4 1 6 4 Calibration of the pH probe To calibrate the probe prepare a glass with clean water Remove the probe from the storage liquid shake off the liquid and stir it in the water Shake it...

Страница 40: ...pH control again stopping the acid pump access the main menu select pH in the last line In the pH menu select the bottom line By pressing OK it alternatively passes from pH ON to pH OFF When the pH c...

Страница 41: ...e probe or probe cable are damaged NOTE to cancel the error alarm press the OK button 4 1 7 Relay The PRO series equipment has a programmable auxiliary relay that can be used to control the filtering...

Страница 42: ...c warning The alarms shutdown the equipment until the problem is solved Similarly it will display a warning also in the 4th line but without an acoustic signal or shutting down the equipment In this c...

Страница 43: ...fins are obstructed or are not in a vertical position Place the equipment so that air is circulated for correct cooling 4 2 1 1 Additional warning messages ORP or PPM value is flashing The redox or f...

Страница 44: ...rn off the equipment and remove the metal body from the plates OPEN CIRCUIT Cell is connected incorrectly Check the cell connection and ensure that cables and connection terminals are in good conditio...

Страница 45: ...eps the water in good conditions in winter time If you still want to use it in low water conditions please consider to reduce the maximum production value for example set it at 50 instead of 100 c Aut...

Страница 46: ...tween each automatic cleaning operation is less This frequency will depend on the hardness of water in your area Submerge the cell in a hydrochloric acid solution or use a commercial product to clean...

Страница 47: ...mmended to clean and check the probe at least once a year Stir it in a glass of water in which a spoonful of detergent has been dissolved Then wash 3 it under the tap and leave it for a few hours in a...

Страница 48: ...rculate through the sensor holders for 1 hour Reading below the DPD 1 measurement Insufficient flow in the sensor holders Adjust the flow reaching the sensor holders Clean the filter and the flow regu...

Страница 49: ...uipment and it is not transferable All chlorinators are checked at the factory before packing If any electrical or mechanical problems occur within 24 months from purchase owing to unlikely malfunctio...