background image

Premium VSD400

Installation and 

Operating Instructions

Model: PM400PV

WARNING: Failure to follow these instructions and comply with all 

applicable codes may cause serious bodily injury and/or property damage.

Please pass these instructions on to the operator of this equipment.

ProMaster

®

This pump requires professional expertise for installation and 

maintenance. The installation of this product therefore should be carried 

out by a person knowledgable in swimming pool plumbing requirements 

and who follows the installation instructions provided in this manual.

Содержание ProMaster Premium VSD400

Страница 1: ...jury and or property damage Please pass these instructions on to the operator of this equipment ProMaster This pump requires professional expertise for installation and maintenance The installation of this product therefore should be carried out by a person knowledgable in swimming pool plumbing requirements and who follows the installation instructions provided in this manual ...

Страница 2: ...ughly water tested against a number of flow pressure voltage current and mechanical performance parameters Davey s advanced pump manufacturing technology provides reliable and efficient pumping performance that lasts and lasts Saving Energy with your Davey ProMaster VSD Pump The Davey ProMaster Pool Spa pump is a super efficient pump utilising a very clever state of the art infinitely variable AC ...

Страница 3: ... is also NORMAL The lower system pressure is simply a result of the lower speed and flow rate produced by the pump While running at the lower speed settings you will also notice a significant reduction in pump noise This is a major benefit for you as it allows you to run your pump during off peak electricity tariffs which will also assist in the reduction of your operating costs Plus you will also...

Страница 4: ...Hz 50 60 Motor Input Power W hp Speed Setting 1 120W 0 16 hp Speed Setting 5 660W 0 89 hp Speed Setting 10 1630W 2 2hp Backwash Setting Variable Operating Limits Max Water temperature 40 C Max Ambient temperature 50 C Dimensions A C E F G H I D B DIMENSIONS mm Model A B C D E F G H I Mounting Holes Diameter Inlet Outlet PVC Net Weight kg PM400PV 305 670 320 350 65 230 380 200 250 10 40 50 14 ...

Страница 5: ...anufacturer with genuine Davey spares This ProMaster pool pump incorporates motor overload detection designed to protect the motor from overheating If the motor gets too hot during operation its operating speed will reduce to bring it within a acceptable operating temperature and then will speed up to the originally set speed To reset the motor switch the power off for 30 seconds and then return t...

Страница 6: ... connected to the inlet connection on the swimming pool filter usually at the filter control valve DUUHO XQLRQV QHHG WR EH KDQG WLJKWHQHG 1R VHDODQW JOXHV RU silicones are required Prior to using this pump you must ensure that Checklist Speed Setting chosen is a compatible setting with other pool equipment F The pump is installed in a safe and dry environment F The pump enclosure has adequate drai...

Страница 7: ...In floor cleaning systems Solar pool heating Guidelines for Recommended Pump Operating Hours Australian Standards AS3633 Private swimming pools water quality states that The minimum turnover rate shall be a single turnover of the full volume of the pool water within the period that the pump would normally be operating The table below provides a guide only to the running times of your pump while in...

Страница 8: ...ngs for programming time for full speed Boost cycling and warnings Solid Green Normal Dial Operation Slow Flashing Green Backwash Fast Flashing Green Boost Cycling AUX External Control Solid Amber Speed Compensation Active Slow Flashing Amber Time to Backwash Fast Flashing Red Fault detected reset pump Constant Flow Speed Compensation Helps to overcomes friction loses experienced as debris builds ...

Страница 9: ...e between a low and high speed to help air rate and agitate the filter media for a more effective clean Reduces wasted water during the backwash cycling process Full variable frequency drive with user friendly selectable speed dial Provides for easy selection of desired filtration speed No complicated digital push button controls Large 4 5 litre lint pot Provides for longer intervals between clean...

Страница 10: ...housing from rear It is recommended to keep the cable length between the pump and external pool controller or heater as short as possible There are two major pin configurations as shown below Figure 2 RJ45 Pin connections Pin Function T 568A T 568B 1 RS485 ve Green White Orange White 2 RS485 ve Green Orange 3 Digital Input 3 Orange White Green White 4 Analogue Input Blue Blue 5 0V Ground Blue Whit...

Страница 11: ...ce for the digital inputs DO NOT power external equipment from this supply rail Digital Control Inputs The 3 digital inputs allow for overriding the dial speed setting To set one of these inputs either 1 Connect an isolated 24V supply between ground and the digital input pin 2 Connect the switched contacts of a relay between the 24V pin and the digital input The fixed speeds as a proportion of ful...

Страница 12: ...ontrolling Equipment To RJ45 Socket of VSD Pump If the controlling equipment does not have 18 24VDC voltage output as above and it has 24VAC 230VAC 12AC or 12 DC etc signal output a suitable relay the coil voltage must be the same as the signal output voltage of the controlling equipment can be used to do this job as mentioned above and shown in the following diagram To RJ45 Socket of VSD Pump Con...

Страница 13: ...ntrol Input Speed control can also be achieved by connecting a 0 10V signal at the input on pin 4 ground at pin 5 As soon as a signal above 0V is registered this input will take priority over dial settings Pin4 Blue Pin5 Blue White 0 10 V DC Signal Output of controlling equipment DC Ground Controlling Equipment To RJ45 Socket of VSD Pump RS485 RS485 inputs are reserved for Davey service connection...

Страница 14: ... of operation 0 5 10 15 20 25 0 50 100 150 200 250 300 350 400 450 Total Head m ProMaster PM400PV Performance Dial position No 10 Dial position No 9 Dial position No 8 Dial position No 7 Dial position No 6 Dial position No 5 Dial position No 4 Dial position No 3 Dial position No 2 Dial position No 1 Flow lpm Speed Setting Input Output Duty Point Flow Rate hp W hp W Dial 1 0 17 125 0 12 87 5 1 2 14...

Страница 15: ...eds 7 to 10 A Davey PoolSweepa suction pool cleaner is recommended to run between speeds 2 to 3 4 The cleaner should only be connected for as long as is required to clean the surface of your pool When cleaning is complete disconnect the cleaner and remove the skimmer plate from the skimmer box 127 7R JHW RSWLPXP HQHUJ HI FLHQF IURP RXU 3UR0DVWHU DO NOT keep the suction pool cleaner connected when ...

Страница 16: ...e lubricated with Hydra slip or equivalent products Failure to undertake regular maintenance may cause damage not covered by warranty Power supply to this pump needs to be through an RCD having a rated leakage current not exceeding 30mA Rainbow Pool Products PO Box 2388 Mansfield Qld 4122 Telephone STD 61 7 3849 5385 Facsimile STD 61 7 3849 5384 Email info rainbowpoolproducts com au Web www rainbo...

Страница 17: ... The pump is not able to get water from the pool Check that the valves to the pump are fully open and that the pool water level is up to the skimmer box 6 Blockage in the piping or pump Remove the strainer basket and check for any blockage to the pump impeller entry Check the skimmer box for blockage If the pump does not operate the following conditions may apply 1 The power is not connected For 2...

Страница 18: ...se the o rings 4 Move the pipework with the barrel unions attached until the pump can be pulled clear NOTE When making any enquiries about your ProMasterbe certain to quote the model number from the nameplate located on the motor Water Quality Maintaining balanced water chemistry is important to the life of your pool pump This pump is designed to be used with Pool Spa water balanced in accordance ...

Страница 19: ...ts are free of leaves and debris at least once a week f Remove obstructions and combustibles from around the pump motor g Make sure all wiring connections are clean and that all wiring and electrical equipment is in good condition Damaged wiring must be UHSDLUHG RU UHSODFHG E D TXDOL HG HOHFWULFLDQ DV VRRQ DV GDPDJH LV discovered h Check water balance and sanitiser levels at your local pool shop W...

Страница 20: ...over normal wear or tear replacement of product consumables i e mechanical seals bearings or capacitors loss or damage resulting from misuse or negligent handling improper use for which the product was not designed or advertised failure to properly follow the provided installation and operating instructions failure to carry out maintenance corrosive or abrasive water or other liquid lightning or h...