91 / 150
Manual PRO50-150 V.2
4.1.7.4- Program OFF
Cancels and details the programs carried out.
4.1.8- Clock
The equipment has a time clock, which will be taken as the reference when
programming times of the auxiliary relay. The clock keeps the time setting even
when the equipment is without supply.
4.2- Warning messages and alarms (PRO)
In the event of abnormal operation, the PRO series equipment will display an
alarm
message on the 4th line of the screen, together with an acoustic
warning. The alarms shutdown the equipment until the problem is solved.
Similarly, it will display a
warning
also in the 4th line, but without an acoustic
signal or shutting down the equipment. In this case, the equipment can
continue operating, although you are informed that corrective action should be
taken.
4.2.1- Warnings
Message:
Causes:
Action required:
"LACK OF SALT"
Lack of salt in the water.
Add salt to the swimming pool.
Incrustations or objects in
the electrolysis cell causing
lack of current.
Clean the cell.
The electrolysis cell is worn.
Replace the electrolysis cell with
a new one.
"EXCESS SALT"
Excess salt in the water.
No action required if excess is
not very significant.