4 The ESPRIT 2 Software
42
The product registration is only
valid for the specified system number.
The system number of the current
hardware is also listed in the product
registration area.
Export system files.
This dialog allows for export all
system relevant setting files as a .zip file.
Product information.
The current version of the
ESPRIT software is displayed here. Please relay this
information to Bruker Service upon service enquiry.
Product registration.
The product registration area
shows the owner’s registration information. Further
details can be accessed by clicking on the
button. This will launch the PDF reader to show the
current product license. If a new license file is
issued, the file in the ESPRIT software can be
updated by clicking the
button. A copy of
the license file is stored to the QUANTAX server’s
profile folder. The license will be checked
automatically by every time the ESPRIT software is
started.
Devices.
The assignment and setup of the X-ray
spectrometer(s) and other devices are normally only
performed during system installation.
The assignment is completely automatic. Each
detector to be assigned must be connected to either
Bruker MegaLink port, a RS232 port, an USB port or
via Ethernet of the QUANTAX server and powered
on when the
button is clicked. All available
ports are automatically scanned for valid
connections. Once the spectrometer is located, the
ESPRIT software must be restarted in order to
register the newly found device.
After the restart of the ESPRIT software the available
detectors are listed within the
Configurator bar
(refer to section 4.5).
Fig. 4.7-2 Detector data dialog
Clicking the
button opens a dialog for setting
the type of spectrometer, the type of the radiation
entrance window, and the geometry parameters.
These entries are loaded from the detector
description file or the detector data sheet.
The motorized detector support can be activated
here. In order to record the acquisition position, click
the
button and follow the wizard.
The
Command
field next to the
button
performs low-level command functions. This is for
troubleshooting purposes by system engineers.
Содержание QUANTAX EDS
Страница 1: ...QUANTAX EDS Energy dispersive X ray spectrometer for electron microscopy User Manual ...
Страница 6: ......
Страница 8: ...User Manual 2 Safety Information 8 ...
Страница 12: ......
Страница 14: ...User Manual 3 The QUANTAX EDS System 14 ...
Страница 22: ......
Страница 24: ......
Страница 48: ......
Страница 50: ...User Manual 5 Step by Step Guides 50 ...
Страница 52: ...User Manual 5 Step by Step Guides 52 Fig 5 1 1 Preparatory steps for measurements with the ESPRIT software ...
Страница 54: ...User Manual 5 Step by Step Guides 54 Fig 5 2 1 Spectrometer calibration ...
Страница 56: ...User Manual 5 Step by Step Guides 56 Fig 5 3 1 Image capture ...
Страница 58: ...User Manual 5 Step by Step Guides 58 Fig 5 4 1 Image extension ...
Страница 60: ...User Manual 5 Step by Step Guides 60 Fig 5 5 1 Image drift correction ...
Страница 62: ...User Manual 5 Step by Step Guides 62 Fig 5 6 1 Image processing ...
Страница 67: ...5 8 Using the Spectrum Chart QUANTAX EDS 67 Fig 5 8 1 Features in the spectrum chart ...
Страница 72: ...User Manual 5 Step by Step Guides 72 Fig 5 10 2 Beam current setting ...
Страница 75: ...5 11 Standards Library QUANTAX EDS 75 Fig 5 11 2 Quantification dialog ...
Страница 85: ...5 12 Quantitative EDS Analysis of Bulk Samples QUANTAX EDS 85 Fig 5 12 2 Automatic standardless quantification ...
Страница 97: ...5 14 Object Analysis QUANTAX EDS 97 Fig 5 14 1 Object analysis ...
Страница 108: ...User Manual 5 Step by Step Guides 108 Fig 5 19 1 Map processing ...
Страница 111: ...5 20 Phase Analysis QUANTAX EDS 111 Fig 5 20 1 Performing phase analysis ...
Страница 113: ...5 21 Creating a Report QUANTAX EDS 113 Fig 5 21 1 Creating a report ...
Страница 116: ......