37
9.5
USER MODE
Below is a description of the display in normal operation according to
the available functions.
Before the ignition of the thermo-stove, the display shows the
following screen (
see drawing D54
): It shows the “off” state, the room
temperature, the established working power and the current time.
9.5.1
IGNITION OF THE STOVE
In order to ignite the thermo-stove, press button no.4 for a few
seconds. The display will show the ignition state as follows (
see
drawing D55
):
The maximum length of the ignition phase is 20 minutes. After this
time, if there is no visible flame, the thermo-stove will automatically go
into the alarm state and the display will show the message “Ignition
Failure.”
9.5.2
STOVE IN OPERATION
Once the set smoke temperature has been reached, the thermo-
stove is working. First of all, it will be in the state “Fire Present” and
this will last just a few minutes before considering the thermo-stove
totally ignited.
In this moment, the display will show the message “Work.” After this,
our thermo-stove will be working normally (
see drawing D56)
.
The display shows the room temperature and the temperature
reached by the circuit water.
9.5.3
CHANGE OF THE SET-POINT ROOM TEMPERATURE
In order to modify the room setting temperature, please press button
2 and then we can modify the temperature by pressing buttons
number 1 and 2 to increase or decrease it respectively.
See drawing
D57
.
If we want the thermo-stove to be controlled by an external thermostat, you should contact the technical
service authorised by Bronpi Calefacción S.L. because it is necessary to activate this external thermostat
in the technical menu. Connection of a volt free signal from a room thermostat or heating controller to the
rear of the thermo-stove, and the correct software parameters is all that is required (
see drawing D58
).
You can find Bronpi external thermostat in the same Bronpi distributor where you bought your
thermo-stove
.
Remember that if you want your thermo-stove to start and stop under the external thermostat demand
you must have the menu “stand-by mode” activated (on). Otherwise, it will modulate when the
water temperature or external thermostat set-point value is reached (the first one which reaches this
temperature).
9.5.4
CHANGE WATER TEMPERATURE SET
In order to modify the set water temperature, please press button
1 and the display will show the current set water temperature. We
can modify the temperature by pressing buttons number 1 and 2 to
increase or decrease it respectively (
see drawing D59
).
14:24
D54
OFF
21ºC 23ºC
24 ºC
SET TEMP
D57
ROOM
14:35
21 ºC P-2
D55
IGNITION
15:18
D56
WORKING
21ºC 53ºC
D59
65º C
SET TEMP.
WATER
4
D51
STATE
SMOKE EXTRACTION SPEED
SMOKE TEMPERATURE FAN 2 AND 3 SPEED (NOT AVAILABLE)
STATE
OPERATIONAL STATE
D52
LOAD
AUGER SPEED
POWER
DIALOGUE
D53
FAILURE
ASPIRATION
STATE
ALARM IN
AL 5
D58
AMBIENT
THERMOSTAT
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
HYDRO SERIES
EN
Содержание Dama Hydro