16
Euro Style Restroom Partitions, Phenolic LT — FLOAT Series
Installation
12/10/2021
Bradley •
AD3-FLOAT_Install Rev. A
13 Riveting Wall Connections
Rivet all parts with the U-bracket to the wall.
Use 4.8 mm x 16 mm stainless steel rivets for
all rivet locations.
Where indicated, rivet all U-brackets to panels and/or
pilasters . Measure down from top edge of U-bracket
approximately 100 mm, up from bottom edge of
U-bracket, and middle of U-bracket, and then pre-drill
using a 5 mm drill bit .
A
Manually insert rivets into the pre-drilled holes . Use a
rivet gun to tighten the rivets into the holes .
B
Glue the cover plates onto the bracket .
C