3
Installation
Euro Style Restroom Partitions, Phenolic LT — FLOAT Series
Bradley •
AD3-FLOAT_Install Rev. A
12/10/2021
When installing the partition components, consult the
applicable Bradley Partition submittal drawing specific to this
job for compartment layout dimensions.
If the centerline dimensions are not specified, the
cubicle is divided equally according to the dimensions
for the front side.
1 Marking & Installing U-Brackets
From the accompanying production drawing, use the
centerline plus overall dimensions and the dimensions
of the front wall . Transfer these measurements to the
floor and appropriate walls .
A
Be aware of your surroundings and avoid obstructions.
Number the wall U-brackets while laying out the stalls .
Use the laser level to locate the drill points for each
U-bracket . Mark and then drill the locations .
B
Using the 4D laser level, locate the centerline of each
U-bracket . Measure up from the floor 100 mm and
mark the bottom of the first U-bracket . Use the first
bracket base location as a guide to locate and mark the
remaining bracket locations using the laser level .
C
Mark the drill holes for the wall connection U-brackets .
Hold the numbered brackets at these locations, line up
the U-bracket pre-drilled holes at laser centerline, and
mark the screw hole locations on the wall . Be sure to
keep the numbered brackets straight .
E
D
Drill the marked holes using an 8 mm drill bit, and
then mount the U-brackets using 8 mm x 51 mm
plastic anchors and 5 .5 mm x 60 mm countersunk
screws with 6 .4 mm washers .
F
The dimensions from the floor for the remaining
U-brackets may vary depending on any slope in the
floor.