15
Installation
Euro Style Restroom Partitions, Phenolic LT — FLOAT Series
Bradley •
AD3-FLOAT_Install Rev. A
12/10/2021
12 Mounting Headrail
Hold the square headrail in the correct position against
the wall and mark the locations of the screw holes .
Drill these wall locations using a 4 .2 mm drill bit .
Insert two 6 mm anchors at these locations .
Slide the square finish end flange over the headrail .
Line up headrail flange against the inserts and screw
in the two 5 .6 mm x 32 mm countersunk screws .
Slide the finish flange over the screw flange using
silicone to secure .
A
When the width of the end pilaster is more than
125 mm wide, attach stabilizers to connect the end
pilasters and headrail . Stabilizers are used to reinforce
the system .
B
If indicated on the drawing, attach the stabilizer to the
top edge of the end pilaster using 4 .8 mm x 50 mm
countersunk screws and to the bottom of the headrail
using 4 .8 mm x 25 mm countersunk screws .
C
The stabilizers are indicated on the drawings if
necessary.