![Boumatic StepMetrix Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/boumatic/stepmetrix/stepmetrix_installation-operation-maintenance-and-service-instructions_2796612006.webp)
4.
StepMetrix location, rotary parlor l864_4
1.3
Reviewing Personal Safety Instructions
To prevent possible bodily injury, foll ow the safety
instructions below and throughout this booklet.
—
Warning ———————————
⎯⎯⎯
9E-864C
StepMetrix™ Installation Instructions
6
Turn off and lockout p ower to the po wer supply before
wiring the power for the St epMetrix. Failure to do s o could
cause serious injury or death.
2.
Installation
The installation of the StepMetrix sy stem is a mult i-
step process. Follow installation steps as described in
the following sections.
— NOTE ———————————————————
⎯⎯
•
Review the instructions on page 1 under the
heading "Responsibilities" and perform only those
steps in this section that you are responsible for
performing.
•
Review the personal safety message s and
installation specifications in Sectio n 1 and
instructions throughout this packet before starting
the procedure(s) in this section.
•
Sides of the sensor module are defined as left
and right, as viewed from the direction of the cow
flow with respect to ¾” (19 mm) load cell conduit.
•
Spacing of StepMetrix co mponents is critical for
best performance. Do not d eviate from
recommended dimensions
•
It may be necessa ry to remove th e existing
railings in the installation area if the exit alleyway
is narrower than the recommended dimensions.
•
The step assembly that is pla ced before the
sensor module will be referred as the StepMetrix
step up, while the ste p assembly that is pla ced
after the sensor module, will be referred as the
StepMetrix step down.
2.1
Installing the StepMetrix with a BouMatic
ID System
2.1.1
Installing the StepMetrix ID Antenna
— NOTE ———————————————————
⎯⎯⎯
•
The placement of the St epMetrix ID a ntenna and
StepMetrix controller determine the placement of th e
entire installation.
•
The wire lengths of the load cell cables and ID antenna
cannot be ch anged; therefore the l ocation of th e
Содержание StepMetrix
Страница 13: ...14 Wiring diagram label P N 3558769 l864_14 StepMetrix Installation Instructions 9E 864C 13 ...
Страница 14: ...9E 864C StepMetrix Installation Instructions 14 14b The control assembly l864_14b 14a Load cell board l864_14a ...
Страница 20: ...9E 864C StepMetrix Installation Instructions 20 21 Load cell locations l864_24 ...
Страница 21: ...22 ISO ID wiring wiring diagram label P N 3559299 l864_25 StepMetrix Installation Instructions 9E 864C 21 ...
Страница 22: ...9E 864C StepMetrix Installation Instructions 22 24 The control assembly l864 27 23 Load cell board l864_26 ...