![Boumatic StepMetrix Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/boumatic/stepmetrix/stepmetrix_installation-operation-maintenance-and-service-instructions_2796612026.webp)
9E-864C
StepMetrix™ Installation Instructions
26
27.
Placing calibration weights on the StepMetrix™ Sensor Module
l864_17
3. StepMetrix needs to know the direction of cow flow with
respect to the load cell conduit. Click on the side (Right
or Left) from which the cows are entering the s ensor
module with respect to the lo ad cell conduit and click
Next.
4. It will then prompt you to remove all the weight on the
sensor module and then press the ZERO b utton. Click
Next to proceed.
5. Place the calibration weights (minimum 450 lbs [205
kg]) on sensor module’s side which has the ¾” (19 mm)
load cell conduit. Enter the calibration weight placed on
the sensor module in th e Weight field and press the
WEIGHT button. T he calibration weights must b e
centered along the length and width of the sensor
module. Click Next to proceed (see Figure 29).
6. Place the calibration weights (minimum 450 lbs [204.11
kg]) on sensor module’s side, opposite the ¾” (19 mm)
load cell conduit. Enter the calibration weight placed on
the sensor module in th e Weight field and press the
WEIGHT button.
7. The calibration weights must be ce ntered along length
and width of the sensor module. Click Next to proceed.
8. Click the COMMIT button to commit the calibration.
9. If all the ‘Ca l Status’ and ‘Diff Status’ messages ar e
displayed ‘OK’, click Next to proceed. Click ‘Finish’ to
complete the calibration procedure. If any of the
message is di splayed as ‘F ailure’ or ‘W arning’, go to
Table 1b of the Troubleshooting Section.
3.
Features
•
StepMetrix is an automated method for ea rly
detection of hoof and leg ailments of hind limbs in
dairy cows. This will help minimize financial
losses resulting from sub-clinical and undetected
clinical lameness.
•
StepMetrix is an observer independent, objective
method of SMX™ scoring dairy cows 24 hours a
day and 7 days a week.
•
StepMetrix is an automate d method of i dentifying
herd and lot SMX™ prevalence.
•
StepMetrix records a hi storical profile o f SMX™
scores of hind limbs for each cow.
4.
Operation
4.1
Understanding Basic StepMetrix Parts
•
StepMetrix step up:
The StepMetrix step up helps
the cow’s transition from floor to t he sensor
module without changing their g ait. It also h elps
to slow down and separate them be fore they
enter the sensor module.
•
StepMetrix sensor module:
The StepMetrix
sensor module consists of left and right platforms,
which are bolted to the load cells. The force from
the cow’s limbs is transferred to these load cells,
Содержание StepMetrix
Страница 13: ...14 Wiring diagram label P N 3558769 l864_14 StepMetrix Installation Instructions 9E 864C 13 ...
Страница 14: ...9E 864C StepMetrix Installation Instructions 14 14b The control assembly l864_14b 14a Load cell board l864_14a ...
Страница 20: ...9E 864C StepMetrix Installation Instructions 20 21 Load cell locations l864_24 ...
Страница 21: ...22 ISO ID wiring wiring diagram label P N 3559299 l864_25 StepMetrix Installation Instructions 9E 864C 21 ...
Страница 22: ...9E 864C StepMetrix Installation Instructions 22 24 The control assembly l864 27 23 Load cell board l864_26 ...