62
Pattern editing (Pattern Edit)
4.
To execute with the specified settings,
press [ENTER]. To cancel, press [EXIT].
The message “Now working...” will appear,
and the copy will be carried out.
When the copy is completed, the message
will disappear.
* If the time signature differs between the copy-source
pattern and the currently selected pattern (copy
destination), the data will be aligned to the time signature
of the currently selected pattern. This will change the
number of measures.
* If you attempt to perform a Copy operation that involves
more than 999 measures, the Copy operation will end
when the number of measures reaches 999.
* If the result of the copy operation has increased the
number of measures in the pattern, the Measures (p. 53)
indication in Patch Information will be updated
automatically.
5.
If you want to save the pattern, proceed
to “Saving a pattern” (p. 65).
Inserting blank measures into
a pattern (Insert Measure)
Here’s how to insert blank measures into the
currently selected pattern.
fig.02-430
1.
In the Pattern Edit menu screen, move the
cursor to the “EDIT” icon and press [ENTER].
fig.02-410d
2.
Move the cursor to the “INSERT” icon
and press [ENTER].
The Insert Measure screen will appear.
fig.02-440d
3.
Move the cursor to each field and use the
VALUE dial to set the desired value.
Choose from the instruments in the currently selected
kit. If you choose ALL, the copy operation will apply to
all instruments of the currently selected kit.
* You can press a pad to specify the instrument.
Times
1–999
Number of times to copy the data
Copy Mode
REPLACE, MERGE Specify how the copy is to take place
REPLACE:
The data at the specified copy destination will be
erased before the source data is copied.
MERGE:
The data at the specified copy destination will be pre-
served, and combined with the copied source data.
* If the Part setting is “CHORD” this parameter will not
appear; the Copy operation is performed using only the
REPLACE method.
* If the Part setting is “ALL,” the Copy operation will
always be performed using REPLACE for the chord
progression.
* Copying with MERGE mode may result in large amounts
of overlapping data being recorded at the same location,
possibly producing unexpected results during playback.
Parameter/
Range
Explanation
Pad bank
Pad number
Instrument
(Ex.)
Parameter/
Range
Explanation
Dest Meas
1–(n+1)
Measure at which blank measures
are to be inserted
* “n” is the number of measures in the current pattern.
Num of Meas
1–(999-n)
Number of blank measures to be in-
serted
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
insert
Содержание Dr. Rhythm DR-880
Страница 2: ......
Страница 21: ...21 Quick Start ...
Страница 48: ...48 ...
Страница 74: ...74 ...
Страница 84: ...84 ...
Страница 115: ...115 Chapter 8 Convenient function System settings ...
Страница 144: ...144 ...
Страница 145: ...145 Appendices ...
Страница 168: ......