en | Configuration using a Web browser
VIP X1 XF
DOC | V4.54 | 2011.09
Installation and Operating Manual
Bosch Sicherheitssysteme GmbH
5.35
Advanced Mode: Alarm Inputs
You can configure the alarm inputs of the VIP X1 XF. The Eco-version only offers one alarm
input.
Alarm input
Select
N.O.
if the alarm is to be triggered when the contact closes. Select
N.C.
if the alarm is
to be triggered when the contact opens.
Name
You can enter a name for each alarm input, which is then displayed below the icon for the
alarm input on the
LIVEPAGE
if configured correctly (see
Section 5.15 Advanced Mode:
LIVEPAGE Functions, page 41
). You can also use the name in the Forensic Search program
function as a filter option for quick search in recordings. Enter a unique and clear name here.
5.36
Advanced Mode: Relay
You can configure the switching behavior of the relay outputs. For each relay, you can specify
an open switch relay (normally closed contact) or a closed switch relay (normally open
contact). The Eco-version only offers one relay output.
You can also specify whether an output should operate as a bistable or monostable relay. In
bistable mode, the triggered state of the relay is maintained. In monostable mode, you can set
the time after which the relay will return to the idle state.
You can select different events that automatically activate an output. It is possible, for
example, to turn on a floodlight by triggering a motion alarm and then turning the light off
again when the alarm has stopped.
CAUTION!
Do not use any special characters, for example
&
, in the name.
Special characters are not supported by the system's internal management.