80
en | Configuration using a Web browser
VIP X1 XF
DOC | V4.54 | 2011.09
Installation and Operating Manual
Bosch Sicherheitssysteme GmbH
5.37
Advanced Mode: COM1
You can configure the serial interface parameters (orange terminal block) to meet your
requirements.
The pin assignment for the serial interface depends on the interface mode that is used:
Serial port function
Select a controllable unit from the list. If you wish to use the serial port to transmit
transparent data, select
Transparent
. Select
Terminal
if you wish to operate the unit from a
terminal.
Standard version
Eco-version
Contact
RS-232 mode
RS-422 mode
RS-485 mode
CTS
—
RxD- (receive data minus)
TXD
TxD (transmit data)
TxD- (transmit data minus)
Data-
RTS
—
TxD+ (transmit data plus)
Data+
RXD
RxD (receive data)
RxD+ (receive data plus)
GND
GND (ground)
—
—
NOTICE!
If the VIP X1 XF is working in multicast mode (see
Section 5.40 Advanced Mode: Multicast,
page 88
), the first remote location to establish a video connection to the unit is also assigned
the transparent data connection. However, after about 15 seconds of inactivity the data
connection is automatically terminated and another remote location can exchange
transparent data with the unit.