56
en | Configuration using a Web browser
VIP X1 XF
DOC | V4.54 | 2011.09
Installation and Operating Manual
Bosch Sicherheitssysteme GmbH
You can define up to ten different recording profiles. You will then use these recording
profiles in the recording scheduler, where they are linked with the individual days and times
(see
Section 5.25 Advanced Mode: Recording Scheduler, page 58
).
1.
Click one of the tabs to edit the corresponding profile.
2.
If necessary, click the
Default
button to return all settings to their default values.
3.
Click the
Copy Settings
button if you want to copy the currently visible settings to other
profiles. A new window will open and you can select the profiles in which you want to
copy the settings.
4.
For each profile, click the
Set
button to save the settings in the unit.
Stream profile settings
You can select the profile setting that is to be used for each data stream in the event of
recordings. This selection is independent of the selection for live data stream transmission
(see
Section 5.20 Advanced Mode: Encoder Streams, page 50
).
The properties of the profiles are defined on the
Encoder Profile
page (see
Section 5.19 Advanced Mode: Encoder Profile, page 47
).
Settings for selected recordings
The settings in this settings group only refer to the recordings selected in the list field. You
can select both recordings.
Recording includes
You can specify whether, in addition to video data, audio data and metadata (for example
alarms, VCA data and serial data) should also be recorded. Including metadata could make
subsequent searches of recordings easier but it requires additional memory capacity.
Standard recording
Here you can select the mode for standard recordings.
If you select
Continuous
, the recording proceeds continuously. If the maximum memory
capacity is reached, older recordings will automatically be overwritten. If you select the
Pre-
alarm
option, the unit uses a special recording mode for optimal usage of storage capacity: As
soon as a time window for alarm recording begins, recording takes place continuously on one
segment that corresponds in size to a complete alarm sequence (pre- and post-alarm time).
This segment functions in a similar manner to a ring buffer and is overwritten until an alarm is
actually triggered. Then, recording occurs on the segment only for the duration of the preset
post-alarm time and a new segment is subsequently used in the same manner.
If you select
Off
, no automatic recording takes place.
NOTICE!
You can change or add to the recording profile description on the tabs on the
Recording
Scheduler
page (see
Section Time periods, page 60
).
CAUTION!
Without metadata, it is not possible to include video content analysis in recordings.
CAUTION!
You can specify limitations for overwriting older recordings in
Continuous
mode by
configuring the retention time (see
Section 5.24 Advanced Mode: Retention Time, page 58
).