16
en | Installation
VIP X1 XF
DOC | V4.54 | 2011.09
Installation and Operating Manual
Bosch Sicherheitssysteme GmbH
4
Installation
4.1
Preparations
Please ensure the following installation conditions:
–
Do not install the unit close to heaters or other heat sources. Avoid locations exposed to
direct sunlight.
–
Allow sufficient space for running cables.
–
Ensure that the unit has adequate ventilation.
–
When making connections, use only the cables supplied or use appropriate cables
immune to electromagnetic interference.
–
Position and run all cables so that they are protected from damage, and provide
adequate cable strain relief where needed.
–
Avoid impacts, blows and severe vibrations that exceed the specification limits (see
Section 9 Specifications, page 121
), as these can irreparably damage the unit.
CAUTION!
The unit is intended for use indoors or in housings.
Select a suitable location for installation that guarantees to meet the environmental
conditions. The ambient temperature must be between 0 and +50 °C (+32 and +122 °F) for
the standard version and between 0 and +60 °C (+32 and +140 °F) for the Eco-version. The
relative humidity must not exceed 95%.
The VIP X1 XF generates heat during operation, so you should ensure that there is adequate
ventilation and enough clearance between the unit and heat-sensitive objects or equipment.