AutoDome Easy II
Preparing the Wiring | en
49
Bosch Security Systems, Inc.
User Manual
F.01U.139.424 | 2.0 | 2009.08
The following figure illustrates the connections for RS485
connections.
Figure 8.3
Connections for RS485 Operations
Wire Type
2-wire Shielded Twisted Pair
Distance
1219 m (4000 ft)
Maximum Baud Rate
57.6 kb
AutoDome Easy II
Head End
Ref. # Wire
Color
Ref. #
Connection
1
C (-) (Biphase)
White/Green
2
C (+) (Biphase) Yellow
3
Ground
White/Orange
8
Head End RS485
4
RS485 (+)
Blue
9
Data (+)
5
RS485 (-)
White/Blue
10
Data (-)
6
Reserved
Violet
11
Ground
7
Reserved
Gray
Содержание VEZ Series
Страница 1: ...AutoDome Easy II VEZ Series en User Manual ...
Страница 2: ......
Страница 18: ...12 en Safety AutoDome Easy II F 01U 139 424 2 0 2009 08 User Manual Bosch Security Systems Inc ...
Страница 22: ...16 en Description AutoDome Easy II F 01U 139 424 2 0 2009 08 User Manual Bosch Security Systems Inc ...
Страница 56: ...50 en Preparing the Wiring AutoDome Easy II F 01U 139 424 2 0 2009 08 User Manual Bosch Security Systems Inc ...
Страница 66: ...60 en Getting Started AutoDome Easy II F 01U 139 424 2 0 2009 08 User Manual Bosch Security Systems Inc ...
Страница 102: ...96 en Pelco On Screen Menus AutoDome Easy II F 01U 139 424 2 0 2009 08 User Manual Bosch Security Systems Inc ...
Страница 108: ...102 en Keyboard Commands by Number AutoDome Easy II F 01U 139 424 2 0 2009 08 User Manual Bosch Security Systems Inc ...
Страница 110: ...104 en Preventive Maintenance AutoDome Easy II F 01U 139 424 2 0 2009 08 User Manual Bosch Security Systems Inc ...
Страница 116: ...110 en Troubleshooting AutoDome Easy II F 01U 139 424 2 0 2009 08 User Manual Bosch Security Systems Inc ...
Страница 122: ...116 en Alternative Control Protocols AutoDome Easy II F 01U 139 424 2 0 2009 08 User Manual Bosch Security Systems Inc ...
Страница 130: ...124 en Index AutoDome Easy II F 01U 139 424 2 0 2009 08 User Manual Bosch Security Systems Inc ...
Страница 131: ......