Diagnostics
8–5
1070 066 091-102 (01.08) GB
8.4
Separate window for cyclic display
The DSS can display any parameters dynamically in separate windows. In
addition to a pure text format, you may also choose a progress bar for dis-
play.
L
Select the menu sequence DIAGNOSES
"
WATCH IDN.
L
Enter the parameter to be displayed in the ”Ident no.” field and a description
in the ”Comment” field, if necessary.
L
Select ”Value” or ”Progress bar” as View type. When ”Progress bar” has
been selected, the desired upper and lower limit may be specified for calibra-
tion purposes.
Display as value ...
Display as value and as
progress bar ...
Result
Result
L
Clicking on ”OK” will close the DSS dialog and display the parameter cycli-
cally in a separate window.
The data display is updated in the intervals set for the ”Module status dis-
.
Parameter values (e.g. setpoints and/or actual values) can also be out-
put via analog outputs (cf. section 5.2.5).
Thus, it is possible to visualize the drive responses, e.g., using a stor-
age oscilloscope.
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01