PROFIBUS-DP interface
3–20
1070 066 091-102 (01.08) GB
Diagnostics class 1
Indication
Description
Bit
0
1
2
I
2
C bus interface error
F60
3
Initialization error: Driver identification
F71
4
Initialization error: ADC-Init
F61
5
Initialization error: Security
F65
6
Initialization error: Overcurrent
F64
Hardware
7
Initialization error: PWM
F62
Hardware
8
Initialization error: Motor-module configuration
F72
9
Initialization error: SERCOS tables
F63
10
11
12
13
Error during RAM test
F51
14
Error when writing parameters
F53
15
Error when reading parameters
F54
0
Encoder does not transmit absolute position
F70
1
Parity error in absolute position
F70
2
Error in zero point storage
F70
3
Timeout when reading via SSI interface
F70
4
Checksum error during data receipt
F70
5
Timeout when writing via SSI interface
F70
6
Number of encoder divisions not defined
F70
Encoder
7
I
2
C bus initialization error
F70
Encoder
8
Errror when reading via I
2
C bus
F70
9
Incorrect number of encoder divisions
F70
10
Encoder parameter has the value 0
F70
11
Timeout when reading via EnDat interface
F70
12
Encoder interface not available
F70
13
Error in EnDat data transmission
F70
14
Error function of EnDat measuring system
F70
15
Encoder not available
F70
0
Non-Maskable Interrupt
H01
1
Stack Overflow
H02
2
Stack Underflow
H03
3
Undefined Opcode
H04
4
Protected Instruction Fault
H05
5
Illegal Word Operation Access
H06
6
Illegal Instruction Access
H07
CPU
7
Illegal External Bus Access
H08
CPU
8
FP – Integer Overflow
H09
9
FP – floating Overflow
H10
10
FP – floating Underflow
H11
11
FP – Divide by Zero
H12
12
FP – undefined float
H13
13
FP – Conversion Error
H14
14
FP – floating point stack underflow
H15
15
FP – floating point stack overflow
H16