Initial commissioning
5–2
1070 066 091-102 (01.08) GB
Your value
Default value
Relevant parameters
Maximum acceleration:
Maximum acceleration capacity, symmetrical for both directions.
S-0-0138 Acceleration bipolar
(changeable in phase 3/4)
3000 rad/s
2
(weighting iaw S-0-0160)
Behavior after ”Drive off” or a fault:
You may choose between:
D
”Halting in shortest possible time” (S-0-0138)
D
”Halting with ramp” (S-0-0260)
D
””Setpoint-controlled halting by master”
The torque will remain active for the duration of the ”Waiting time drive
off” (S-0-0207).
P-0-0004 Halting mode with drive off
(changeable in phase 2)
0b0000.0000.0000.0000
(= in shortest possible time)
Behavior after removal of the external drive enable signal:
You may choose between:
D
”Halting without setpoint control”
D
”Effect depends on P-0-0004”
(the torque will remain active for the duration of the ”Waiting time drive
off” (S-0-0207)).
P-0-0125 Control word ext. Enable
(changeable in phase 2)
0b0000.0000.0000.0000
(= effect depends on P-0-0004)
Holding brake:
”Waiting time drive on” accounts for the time required for releasing the
brake, thus preventing excessive wear:
D
The ”Drive on”
and
”Drive enable” signals will first activate the torque,
depending on P-0-0505 (Plug brake enable delay).
D
The drive will not follow the setpoint input before the ”Waiting time
drive on” has elapsed.
”Waiting time drive off” prevents the axis from jerking caused by the re-
moval of the torque while the holding brake has not yet engaged.
S-0-0206 Waiting time drive on
(changeable in phase 3/4)
S-0-0207 Waiting time drive off
(changeable in phase 3/4)
0 ms
0 ms
Plug braking:
When the ”Drive on”
and
”Drive enable” signals have been set, the
torque will not become active unless P-0-0505 has elapsed. This is to
prevent that the motor power is connected although the braking resistors
are still active on the motor line because of hardware-related delays
when deactivating the braking resistors.
P-0-0505 KSB enable delay
(changeable in phase 2/3/4)
0 ms
L
Select EXTRAS
"
INITIALIZATION GUIDE.
The initialization guide will lead you step-by-step through the basic parame-
ter setting process.
Once the individual steps have been passed, you may send the basic pa-
rameter settings directly to the drive.
If necessary, the data may be additionally saved in a *.scs file.
Alternatively
, you may use the monitor instead of the initialization guide in
order to adapt all values to your needs and transmit them to the drive.
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01