Prerequisites for commissioning
2–1
1070 066 091-102 (01.08) GB
2
Prerequisites for commissioning
Drive inverters of the Servodyn-D series with PROFIBUS-DP are operated
as slaves of a PROFIBUS-DP master.
For the inverters, a GSD file is available (device master data) which contains
all data required for operating Servodyn-D on any master compliant to
EN 50170-2-DP. The manufacturer of the DP master supplies a suitable
configuration tool which you may use to link the drive inverter to the PROFI-
BUS environment.
.
In this manual, we have assumed that the necessary knowledge for
configuring PROFIBUS-DP is available.
The commissioning procedure comprises the following steps:
D
Set PROFIBUS addresses on the drives (S2, S3) and establish PROFI-
BUS connections (X51).
D
Establish communication between the DSS (Diagnostics and Service
System) and the drive (X99)
D
Load GSD file into the DP master
D
Configure PROFIBUS-DP telegrams using the PROFIBUS services
”Set_Param” and ”Check_Config”.
Please note the detailed information provided in section 3.
D
Adjust/optimize all required drive parameter values.
This has to be done using the DSS.
.
The DSS is designed for PCs on which the Windows
t
operating sys-
tem has been installed.
The installation and operation of the DSS requires general knowledge
of the Windows user interface (e.g. start/exit programs, open/save
files, change program windows, etc.).
In the present manual, we suppose that this knowledge is available.
CAUTION
Commissioning by insufficiently qualified personnel may cause se-
vere damage to the machine and drives or even personal injury!
D
Commissioning is therefore reserved to appropriately trained
technical personnel!
D
For systems comprising several drives, you should always op-
timize one drive at a time only.
D
All motors have to be properly fastened.
Our service department will be pleased to assist you with the commission-
ing. We may also train your personnel on request. For more information,
please contact us (phone +49-(0)6062/78-0)
.
The description of all individual parameters, their mode of functioning
and precise programming is included in the ”Servodyn-D parameter
manual”. This description forms the basis of the present manual!
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01