DSS user interface
4–4
1070 066 091-102 (01.08) GB
4.2
DSS monitor
The DSS monitor offers direct
Online access
to all parameters stored in the
drive.
You may:
D
edit parameters
D
save a list of several parameters as initialization file (*.scs) of the drive.
For each drive, several *.scs files can be created, e.g. for certain drive
functions or commissioning steps
D
transmit imported *.scs files to the drive (cf. page 4–7)
.
Whether or not several instances of the DSS monitor can be started,
can be configured by selecting the ”Open DSS monitor only once”
checkbox on the ”Global” tab of the EXTRAS
"
PREFERENCES menu.
L
Start the Monitor by
D
the menu sequence DISPLAY
"
MONITOR – or –
D
Icon bar: Click on
– or –
D
"
MONITOR in the ”Overview” window.
Name of parameter in plain text (cannot be changed)
Current
changeable
parameter number
Current
changeable
pa-
rameter value. When the
”Data” text appears
dimmed, the data cannot
be changed.
Input limits of the current
parameter
Parameter list.
Double-click on one of
the parameters to dis-
play its information in
the upper fields.
Read current pa-
rameter from the
drive
Transfer current
parameter to the
drive. Parameter
change becomes
immediately active.
Save all parame-
ters in the list as
*.scs file.
Read all parame-
ters of a *.scs file
and display them in
a list.
This field contains all parameters that have been
read or imported at least once since the last
monitor call.
Single parameter
1. Click on the ”Ident. no” field
2. Enter the parameter number to be edited.
The following syntax options may be used:
D
complete, e.g. ”S-0-0040” or ”P-0-0100”
D
simplified, e.g. ”s40” or ”p100”
D
only the number, e.g. ”40” instead of ”S-0-0040” (factory setting).
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01