1
2
L
R
+
-
1
2
L
R
①
View onto cable output or terminal box
②
Direction of rotation of the rotor with phase sequence U-V-W
+
Positive count direction of the encoder = assumption (observe
the count direction defined in the encoder data sheet)
-
Negative count direction of the encoder = assumption (observe
the count direction defined in the encoder data sheet)
L
S-0-0277 bit 3 set to "1" if the encoder is rotating to the right;
S-0-0277 bit 3 set to "0" if the encoder is rotating to the left
R
S-0-0277 bit 3 set to "0" if the encoder is rotating to the right;
S-0-0277 bit 3 set to "1" if the encoder is rotating to the left
Fig. 13-2:
Direction of rotation of the rotor, as viewed from the cable output
side at the stator (MST)
When adjusting the polarity of the encoder, ensure that the count
direction of the encoder and the direction of rotation of the motor
are the same.
If this is not the case, the encoder polarity has to be adjusted via
parameter S-0-0277 bit 3.
Parameter
Description
Position of bit 3
S-0-0277
Position feedback type 1
000000000000>0<000
Tab. 13-4:
Parameter S-0-0277
390/409
Commissioning, operation and maintenance
MBT High Synchronous Torque Motors
Bosch Rexroth AG R911298798_Edition 08
Содержание rexroth MBT
Страница 1: ...MBT High Synchronous Torque Motors Project Planning Manual R911298798 Edition 08 ...
Страница 18: ...6 409 MBT High Synchronous Torque Motors Bosch Rexroth AG R911298798_Edition 08 ...
Страница 32: ...20 409 MBT High Synchronous Torque Motors Bosch Rexroth AG R911298798_Edition 08 ...
Страница 240: ...228 409 MBT High Synchronous Torque Motors Bosch Rexroth AG R911298798_Edition 08 ...
Страница 298: ...286 409 MBT High Synchronous Torque Motors Bosch Rexroth AG R911298798_Edition 08 ...
Страница 416: ...404 409 MBT High Synchronous Torque Motors Bosch Rexroth AG R911298798_Edition 08 ...
Страница 421: ...Notes MBT High Synchronous Torque Motors 409 409 ...