Before connecting the motor, the following steps have to be taken by the ma‐
chine manufacturer:
1. Decision about connection type terminal box or device connector as well
as acquisition of the components required.
2. Shortening the power cable to the desired length (only if required).
3. Cutting the cables to length for the connection at the motor, according to
documentation "Rexroth Connection Cables IndraDrive and IndraDyn"
(DOK-CONNEC-CABLE*INDRV-AU□□-□□-P).
4. Fastening the coupling and the cable harness to the machine.
Pay particular attention to the following issues when cutting the cables to
length and installing the connections:
●
Careful execution of the ground connection and the shield connection to
meet EMC directives.
●
Careful execution of the tightening and plug-in connections to comply
with the safety class.
●
Power cables for connection to the controller or drive are not included in
the scope of delivery of the motor and have to be ordered separately.
●
Do not open or loosen the factory-assembled cable glands at the stator.
●
The coolants, lubricants and fuels used at the machine should not dam‐
age the lines and connection cables used nor modify them chemically or
with regard to the structure.
Terminal box
Terminal boxes or single components for connecting stators with connection
cable are not delivered by Rexroth. Possible suppliers are:
Components
Supplier
Terminal box
KIENLE & SPIESS GmbH
Bahnhofstrasse 23
74343 Sachsenheim, Germany
Phone: +49 (0) 71 47 29 - 0
Fax: +49 (0) 71 47 29 - 1488
Internet:
Terminal board
REKOFA WENZEL GmbH & Co. KG
Walporzheimer Strasse 100
53474 Bad Neuenahr - Ahrweiler, Germany
Phone: +49 (0) 26 41 / 387 - 0
Fax: +49 (0) 26 41 / 387 - 33 95
Terminal strip
WIELAND ELECTRIC GmbH
Benzstrasse 9
96052 Bamberg, Germany
Internet:
Tab. 8-4:
Suppliers of terminal boxes
When selecting the components, take the following into consideration...
●
that the components have to be suitable for currents and voltage of the
chosen drive system. In particular for high DC bus voltages up to 750
V
DC
.
246/409
Connection technique
MBT High Synchronous Torque Motors
Bosch Rexroth AG R911298798_Edition 08
Содержание rexroth MBT
Страница 1: ...MBT High Synchronous Torque Motors Project Planning Manual R911298798 Edition 08 ...
Страница 18: ...6 409 MBT High Synchronous Torque Motors Bosch Rexroth AG R911298798_Edition 08 ...
Страница 32: ...20 409 MBT High Synchronous Torque Motors Bosch Rexroth AG R911298798_Edition 08 ...
Страница 240: ...228 409 MBT High Synchronous Torque Motors Bosch Rexroth AG R911298798_Edition 08 ...
Страница 298: ...286 409 MBT High Synchronous Torque Motors Bosch Rexroth AG R911298798_Edition 08 ...
Страница 416: ...404 409 MBT High Synchronous Torque Motors Bosch Rexroth AG R911298798_Edition 08 ...
Страница 421: ...Notes MBT High Synchronous Torque Motors 409 409 ...