8
Maintenance and Installation
8.1
General Information
The Embedded Terminal IndraControl VEP **.4s are maintenance-free. How‐
ever, some components are subject to wear and must be replaced.
Maintenance work in the device is only permissible by skilled staff!
If hardware or software components have to be exchanged, please
contact the Bosch Rexroth Service or ensure that only skilled staff
changes the respective components.
In order to avoid incorrect operation, clean the devices only when
they are switched off.
Maintenance
Include the following measures in the maintenance schedule:
●
Clean the screen at least once a week using an antistatic fabric or a
cleansing agent containing alcohol when the device is switched off. Avoid
hard objects that may cause scratches.
Dissolution of the foil surface as well as the
display seal by solvents or by high pressure
cleaning devices!
NOTICE
●
Do not use any solvents (e. g. diluents)!
●
Do not use compressed air, steam jet and high pressure cleaning devices!
●
At least once a year, check all plug and terminal connections of the com‐
ponents regarding proper tightness and possible damage. Check that
cables are not broken or crushed. Replace damaged parts immediately.
●
Check the fan at least once a year.
Risk of injury by rotating fan impeller!
DANGER
The fan impeller must not be touched by persons or come in contact with other
objects.
Function compatibility for spare parts is ensured for at least five
years.
8.2
LC Display
A fading backlight causes a progressive deterioration of the readability of the
LCD display, so that a backlight exchange is required. For further information
please contact the Bosch Rexroth Service.
8.3
CMOS Battery
The IndraControl VEP **.4 devices are provided with a lithium battery to buffer
the real-time clock in the BIOS. If this battery is empty or weak, the clock setting
is lost in the BIOS.
DOK-SUPPL*-VEP*XX.4***-PR03-EN-P
Rexroth IndraControl VEP **.4 Embedded Terminal
Bosch Rexroth AG
93/139
Maintenance and Installation
Содержание Rexroth IndraControl VEP 30.4
Страница 1: ...Electric Drives and Controls Pneumatics Service Linear Motion and Assembly Technologies Hydraulics ...
Страница 8: ...Bosch Rexroth AG DOK SUPPL VEP XX 4 PR03 EN P Rexroth IndraControl VEP 4 Embedded Terminal VI 139 ...
Страница 26: ...Bosch Rexroth AG DOK SUPPL VEP XX 4 PR03 EN P Rexroth IndraControl VEP 4 Embedded Terminal 24 139 ...
Страница 36: ...Bosch Rexroth AG DOK SUPPL VEP XX 4 PR03 EN P Rexroth IndraControl VEP 4 Embedded Terminal 34 139 ...
Страница 78: ...Bosch Rexroth AG DOK SUPPL VEP XX 4 PR03 EN P Rexroth IndraControl VEP 4 Embedded Terminal 76 139 ...
Страница 126: ...Bosch Rexroth AG DOK SUPPL VEP XX 4 PR03 EN P Rexroth IndraControl VEP 4 Embedded Terminal 124 139 ...
Страница 134: ...Bosch Rexroth AG DOK SUPPL VEP XX 4 PR03 EN P Rexroth IndraControl VEP 4 Embedded Terminal 132 139 ...
Страница 136: ...Bosch Rexroth AG DOK SUPPL VEP XX 4 PR03 EN P Rexroth IndraControl VEP 4 Embedded Terminal 134 139 ...
Страница 140: ...Bosch Rexroth AG DOK SUPPL VEP XX 4 PR03 EN P Rexroth IndraControl VEP 4 Embedded Terminal 138 139 ...
Страница 141: ...Notes DOK SUPPL VEP XX 4 PR03 EN P Rexroth IndraControl VEP 4 Embedded Terminal Bosch Rexroth AG 139 139 ...