Designa‐
tion at the
housing
Connection type
Connector type
(integrated)
Mating connector or
line
(from outside)
XUSB
USB interfaces, USB 1 and USB
2
USB female con‐
nector, type A
4-pin
USB connector,
4-pin
XS1
DC 24 V voltage supply
Connector strip,
SL pin spacing 3.5
mm, 5-pin
Female connector
strip,
BL pin spacing 3.5
mm, 5-pin
X7E3
X7E4
Fieldbus connection:
For Ethernet-based bus sys‐
tems
RJ45 female con‐
nector,
8-pin
RJ45 connector,
twisted pair,
8-wire
X7P
PROFIBUS DP Master
D-Sub female con‐
nector,
9-pin
D-Sub bus connec‐
tor,
9-pin
X7S1 to
X7S4
SERCOS III interfaces
RJ45 female con‐
nector,
8-pin
RJ45 connector,
twisted pair,
8-wire
Fig.7-6:
Interfaces of the VEP Pentium M devices
VEP ATOM devices
Designa‐
tion at the
housing
Connection type
Connector type
(integrated)
Mating connector or
line
(from outside)
XCF1, 2
Compact Flash socket
CF1 primary Master
CF2 primary Slave
CF socket
CF card
XETH
Network connection:
Ethernet 10 Base T or 100 Base
X
RJ45 female con‐
nector,
8-pin
RJ45 connector,
twisted pair,
8-wire
XUSB1/2 USB interfaces, USB 1 and USB
2
USB female con‐
nector, type A
4-pin
USB connector,
4-pin
XS1
DC 24 V voltage supply
Connector strip,
SL pin spacing 3.5
mm, 3-pin
Female connector
strip,
BL pin spacing 3.5
mm, 3-pin
XCOM
COM interface
D-SUB, 9-pin
D-SUB, 9-pin
Fig.7-7:
Interfaces of the VEP ATOM devices
7.2.3
DC 24 V Voltage Supply XS1
All internally required voltages are generated via a DC/DC converter. The con‐
nection is designed as male connector strip SL 3.5 mm pin spacing, 3-pin or 5-
pin. To this connector terminal, cables with a cross-section of maximum
1.5 mm
2
can be connected.
VEP Pentium M devices
The VEP Pentium devices feature a 5-pin connection terminal
DOK-SUPPL*-VEP*XX.4***-PR03-EN-P
Rexroth IndraControl VEP **.4 Embedded Terminal
Bosch Rexroth AG
85/139
Pin Assignments
Содержание Rexroth IndraControl VEP 30.4
Страница 1: ...Electric Drives and Controls Pneumatics Service Linear Motion and Assembly Technologies Hydraulics ...
Страница 8: ...Bosch Rexroth AG DOK SUPPL VEP XX 4 PR03 EN P Rexroth IndraControl VEP 4 Embedded Terminal VI 139 ...
Страница 26: ...Bosch Rexroth AG DOK SUPPL VEP XX 4 PR03 EN P Rexroth IndraControl VEP 4 Embedded Terminal 24 139 ...
Страница 36: ...Bosch Rexroth AG DOK SUPPL VEP XX 4 PR03 EN P Rexroth IndraControl VEP 4 Embedded Terminal 34 139 ...
Страница 78: ...Bosch Rexroth AG DOK SUPPL VEP XX 4 PR03 EN P Rexroth IndraControl VEP 4 Embedded Terminal 76 139 ...
Страница 126: ...Bosch Rexroth AG DOK SUPPL VEP XX 4 PR03 EN P Rexroth IndraControl VEP 4 Embedded Terminal 124 139 ...
Страница 134: ...Bosch Rexroth AG DOK SUPPL VEP XX 4 PR03 EN P Rexroth IndraControl VEP 4 Embedded Terminal 132 139 ...
Страница 136: ...Bosch Rexroth AG DOK SUPPL VEP XX 4 PR03 EN P Rexroth IndraControl VEP 4 Embedded Terminal 134 139 ...
Страница 140: ...Bosch Rexroth AG DOK SUPPL VEP XX 4 PR03 EN P Rexroth IndraControl VEP 4 Embedded Terminal 138 139 ...
Страница 141: ...Notes DOK SUPPL VEP XX 4 PR03 EN P Rexroth IndraControl VEP 4 Embedded Terminal Bosch Rexroth AG 139 139 ...