Circulating currents
Circulating currents are defined as currents which do not flow as desired from the
positive pole of the welding equipment through the workpiece and to the negative
pole of the welding equipment during the welding process, but rather through the
workpiece and then through external ”ground connections” and the protective con-
ductor jumper (MPE) to the negative pole.
When do circulating currents occur?
Case 1
+
--
U
V
PE
Transformer
Rectifier
MPE
Housing
Workpiece
(
(
(
Supply line
Negative pole grounded through protective conductor jumper (MPE), workpiece
not grounded (ideal arrangement).
Circulating currents are not possible.
Case 2
+
--
Transformer
Rectifier
MPE
Housing
Workpiece
U
V
PE
(
(
Supply line
(
Negative pole grounded via protective conductor jumper (MPE), workpiece
grounded, transformer housing insulated from
.
There will be circulating currents through the mains supply line.
Содержание PSG 3000 Series
Страница 1: ...PSU 5000 PSG 3000 Instructions for Assembly and Operation MF Welding Inverters 109 Version ...
Страница 3: ......
Страница 5: ...PSU 5000 PSG 3000 Instructions for Assembly and Operation 1070 078 224 109 ...
Страница 57: ...PSU 5000 PSG 3000 Monitoring and diagnostics Instructions for Assembly and Operation 1070 078 224 108 7 6 ...
Страница 79: ...PSU 5000 PSG 3000 Installation Cooling Instructions for Assembly and Operation 1070 078 224 108 10 12 ...
Страница 97: ...PSU 5000 PSG 3000 Connection Instructions for Assembly and Operation 1070 078 224 109 11 18 ...
Страница 101: ...PSU 5000 PSG 3000 Maintenance Instructions for Assembly and Operation 1070 078 224 108 13 2 ...
Страница 105: ...PSU 5000 PSG 3000 Instructions for Assembly and Operation Accessories 1070 078 224 108 14 4 ...
Страница 107: ...PSU 5000 PSG 3000 Instructions for Assembly and Operation Storage and transport 1070 078 224 108 15 2 ...
Страница 109: ...PSU 5000 PSG 3000 Instructions for Assembly and Operation Declaration of conformity 1070 078 224 108 16 2 ...
Страница 113: ...PSU 5000 PSG 3000 Instructions for Assembly and Operation Index 1070 078 224 109 17 4 ...
Страница 114: ...1070 078 224 109 98 10 GB MBA AT VWS Printed in Germany ...