PSU 5000 / PSG 3000
Connection
Instructions for Assembly and Operation
1070 078 224--109
11--8
11.4 Connection between PSU and timer module
Control option: 5 kHz firing pulses (cf. also Section 8.1)
PSU
yellow
green
Weld timer
1
10
1
3
X5
X12
27 V AC supply (synchronization)
5) 1)
temperature contact
2)
temperature contact
2)
ig
ignition --
+24 V
1)
0 V
1)
1)
1
: When operated with timers of the E81...DYD and ZPS
series terminals 1, 2 and 8 to 10 of X5 are
not
used.
2
: “Overtemperature” or “Inverter fault” message
3
: Required for actual---value message from PSU to timer
with built---in KSR module for DC operation
Conductor cross--section up to 10 m: 0.75 mm
2
Conductor cross--section up to 75 m: 1.5 mm
2
Connecting cable
3)
: 2 x 2 x 0.75 mm
2
shielded LiYCY
The cable and mating connectors are not
included in the delivery!
For part no., see section 14
When used together with timers operating
with the SSU function, switch 1 of DIP
switch bank S2 must remain ON (cf.also
Section 9.6)
1 kOhm
load imped-
ance
B
K
2
3
4
5
6
7
8
9
2
4
: A change---over contact serves as temperature contact
of the PSU, i.e. it may be used
--- as a normally---open contact (connection between
X5/4 and X5/5)
--- or as a normally---closed contact (connection
between X5/5 and X5/10).
4)
4
5
6
27 V AC supply (synchronization)
5) 1)
5
: The synchronization voltage may vary between
21 VAC and 36 VAC, depending on the inverter type
and mains supply voltage. The maximum load is
approx. 3 mA.
NOTE
Please note that if timer types ”ZPS”, ”E81...DYD”, and ”PSS 2000” are used, the
synchronization voltage (which also serves as timer supply voltage) for these
timers must be generated externally and cannot be derived from pins 1 and 2 of X5
(cf. section 11.2.2).
Содержание PSG 3000 Series
Страница 1: ...PSU 5000 PSG 3000 Instructions for Assembly and Operation MF Welding Inverters 109 Version ...
Страница 3: ......
Страница 5: ...PSU 5000 PSG 3000 Instructions for Assembly and Operation 1070 078 224 109 ...
Страница 57: ...PSU 5000 PSG 3000 Monitoring and diagnostics Instructions for Assembly and Operation 1070 078 224 108 7 6 ...
Страница 79: ...PSU 5000 PSG 3000 Installation Cooling Instructions for Assembly and Operation 1070 078 224 108 10 12 ...
Страница 97: ...PSU 5000 PSG 3000 Connection Instructions for Assembly and Operation 1070 078 224 109 11 18 ...
Страница 101: ...PSU 5000 PSG 3000 Maintenance Instructions for Assembly and Operation 1070 078 224 108 13 2 ...
Страница 105: ...PSU 5000 PSG 3000 Instructions for Assembly and Operation Accessories 1070 078 224 108 14 4 ...
Страница 107: ...PSU 5000 PSG 3000 Instructions for Assembly and Operation Storage and transport 1070 078 224 108 15 2 ...
Страница 109: ...PSU 5000 PSG 3000 Instructions for Assembly and Operation Declaration of conformity 1070 078 224 108 16 2 ...
Страница 113: ...PSU 5000 PSG 3000 Instructions for Assembly and Operation Index 1070 078 224 109 17 4 ...
Страница 114: ...1070 078 224 109 98 10 GB MBA AT VWS Printed in Germany ...