![Bosch PSG 3000 Series Скачать руководство пользователя страница 77](http://html.mh-extra.com/html/bosch/psg-3000-series/psg-3000-series_instructions-for-assembly-and-operation-manual_52968077.webp)
PSU 5000 / PSG 3000
Installation
Cooling
Instructions for Assembly and Operation
1070 078 224--108
10--10
10.4 Installation and assembly
ATTENTION!
-- Danger of life and of damage to property through insufficient protection class!
The protection class of the PSU modules is IP 20. PSU modules must be instal-
led in a switch cabinet which must at least comply with protection class IP 54 (cf.
also Section 5, ”Technical Data”).
When delivered, the protection class of the primary connecting zone of all PSG
modules is IP 00 (cf. also Section 5, ”Technical Data”). It must be covered with a
suitable terminal box (cf. Section 14, ”Accessories”) in order to increase the pro-
tection class of the primary connection zone to IP 55.
-- Danger of injury and of damage to property through incorrect installation!
The units, and especially the operating elements, must be installed so as to be
sufficiently protected against unintentional operation or contact.
-- Danger of injury or of damage to property due to inappropriate fastening!
The place for installing the modules, and their method of fastening, must be sui-
table for their weight!
-- Injuries and bruises may be caused by lifting weights which are too heavy or by
sharp metal edges!
Due to the heavy weight of individual modules (for weight data, see Section 5,
”Technical Data”) several persons are required for installation and assembly.
Please observe all applicable safety and accident prevention regulations! Wear
safety shoes and safety gloves!
-- Danger of damage to property through short--circuits!
When drilling or sawing out openings within switch cabinets, metal burr may get
inside modules that have already been installed. It is also possible that water
may emerge during the installation of the cooling water lines and may enter the
modules.
The possibility of short--circuits and a destruction of the units cannot be entirely
ruled out.
Therefore, the modules should be well partitioned prior to any additional work!
No liability is accepted in the event of non--compliance.
-- Damages to property through leaks in the cooling water circuit!
A leak in the cooling water circuit may cause damages to adjacent components
through emerging cooling water. Therefore you should install the modules so as
to sufficiently protect other units in the switch cabinet against leaking cooling
water.
!
Содержание PSG 3000 Series
Страница 1: ...PSU 5000 PSG 3000 Instructions for Assembly and Operation MF Welding Inverters 109 Version ...
Страница 3: ......
Страница 5: ...PSU 5000 PSG 3000 Instructions for Assembly and Operation 1070 078 224 109 ...
Страница 57: ...PSU 5000 PSG 3000 Monitoring and diagnostics Instructions for Assembly and Operation 1070 078 224 108 7 6 ...
Страница 79: ...PSU 5000 PSG 3000 Installation Cooling Instructions for Assembly and Operation 1070 078 224 108 10 12 ...
Страница 97: ...PSU 5000 PSG 3000 Connection Instructions for Assembly and Operation 1070 078 224 109 11 18 ...
Страница 101: ...PSU 5000 PSG 3000 Maintenance Instructions for Assembly and Operation 1070 078 224 108 13 2 ...
Страница 105: ...PSU 5000 PSG 3000 Instructions for Assembly and Operation Accessories 1070 078 224 108 14 4 ...
Страница 107: ...PSU 5000 PSG 3000 Instructions for Assembly and Operation Storage and transport 1070 078 224 108 15 2 ...
Страница 109: ...PSU 5000 PSG 3000 Instructions for Assembly and Operation Declaration of conformity 1070 078 224 108 16 2 ...
Страница 113: ...PSU 5000 PSG 3000 Instructions for Assembly and Operation Index 1070 078 224 109 17 4 ...
Страница 114: ...1070 078 224 109 98 10 GB MBA AT VWS Printed in Germany ...