PSU 5000 / PSG 3000
Instructions for Assembly and Operation
Installation
Cooling
1070 078 224--108
10--11
-- Damage to property through insufficient water quality in the cooling water cir-
cuit!
Deposits in the cooling system may reduce the water flow, thus impairing the
performance of the cooling system with time.
Therefore, you should ensure that your cooling water has the following proper-
ties:
-- pH value: 7 to 8.5
-- Degree of hardness D
max
: 10 German degrees
(1 German degree = 1.25 British degrees = 1.05 US degrees = 1.8 French
degrees)
-- Chlorides: max. 20 mg/l
-- Nitrates: max. 10 mg/l
-- Sulfates: max. 100 mg/l
-- Insoluble substances: max. 250 mg/l
Tap water usually meets these requirements. However, an algicide should be
added.
NOTE
-- Connecting lines and signal lines must be laid so as to avoid negative effects on
the function of the units through capacitive or inductive interference!
-- Interference is frequently coupled and de--coupled in long cables. Therefore,
inverter cables and control cables must be routed separately. The influence of
interfering cables on cables susceptible to interference can be minimized by
keeping the following distances:
> 100 mm with parallel connection of cables < 10 m
> 250 mm with parallel connection of cables > 20 m.
Install the inverters near the welding equipment in order to avoid cable lengths
> 25 m wherever possible.
-- A clearance of min. 100 mm must be available above and below air--cooled
modules. Lower clearances induce the danger of heat accumulations which
may result in a failure of the unit.
Содержание PSG 3000 Series
Страница 1: ...PSU 5000 PSG 3000 Instructions for Assembly and Operation MF Welding Inverters 109 Version ...
Страница 3: ......
Страница 5: ...PSU 5000 PSG 3000 Instructions for Assembly and Operation 1070 078 224 109 ...
Страница 57: ...PSU 5000 PSG 3000 Monitoring and diagnostics Instructions for Assembly and Operation 1070 078 224 108 7 6 ...
Страница 79: ...PSU 5000 PSG 3000 Installation Cooling Instructions for Assembly and Operation 1070 078 224 108 10 12 ...
Страница 97: ...PSU 5000 PSG 3000 Connection Instructions for Assembly and Operation 1070 078 224 109 11 18 ...
Страница 101: ...PSU 5000 PSG 3000 Maintenance Instructions for Assembly and Operation 1070 078 224 108 13 2 ...
Страница 105: ...PSU 5000 PSG 3000 Instructions for Assembly and Operation Accessories 1070 078 224 108 14 4 ...
Страница 107: ...PSU 5000 PSG 3000 Instructions for Assembly and Operation Storage and transport 1070 078 224 108 15 2 ...
Страница 109: ...PSU 5000 PSG 3000 Instructions for Assembly and Operation Declaration of conformity 1070 078 224 108 16 2 ...
Страница 113: ...PSU 5000 PSG 3000 Instructions for Assembly and Operation Index 1070 078 224 109 17 4 ...
Страница 114: ...1070 078 224 109 98 10 GB MBA AT VWS Printed in Germany ...