PSU 5000 / PSG 3000
Connection
Instructions for Assembly and Operation
1070 078 224--109
11--10
11.5 Connection between PSU and PSG
PSU
green
yellow
PSG
Connecting cable: 2 x 2 x
0.75 mm
2
shielded LiYCY
The cable and the 12--pole
mating connector are not in-
cluded in the delivery! For
part no., see section 14.
white
brown
3 thermostatic
switches connected
in series
white
brown
black
yellow
current sensor
U
V
to PSU power feeders
(cf. Section 11.3)
--
+
to the electrodes
Brush leads approx. 150 mm long.
The connector makes, if any, are
customer--specific and are available
as accessories.
MPE
1
3
X11
2
4
5
6
1)
1)
A suitable sensory
mechanism can be
connected to pins 5
and 6 for electrode
voltage feedback in
the event of closed--
loop power control.
WARNING!
Danger through electrical voltage!
The protective earth for the negative pole of the PSG can be interrupted by opening
the protective earth conductor connection at the PSG (see MPE point in diagram
above). In order to protect the operating personnel against dangerous electrical
voltages in the event of a break--down of the transformer primary side to the secon-
dary side, in this case, a suitable protective measure pursuant to DIN 57 113,
VDE 0113 is to be provided (e.g. by earthing the welding gun)! In addition, the
transformer is to be marked accordingly (see also dimension drawing of the trans-
former, Section 10.2).
!
Содержание PSG 3000 Series
Страница 1: ...PSU 5000 PSG 3000 Instructions for Assembly and Operation MF Welding Inverters 109 Version ...
Страница 3: ......
Страница 5: ...PSU 5000 PSG 3000 Instructions for Assembly and Operation 1070 078 224 109 ...
Страница 57: ...PSU 5000 PSG 3000 Monitoring and diagnostics Instructions for Assembly and Operation 1070 078 224 108 7 6 ...
Страница 79: ...PSU 5000 PSG 3000 Installation Cooling Instructions for Assembly and Operation 1070 078 224 108 10 12 ...
Страница 97: ...PSU 5000 PSG 3000 Connection Instructions for Assembly and Operation 1070 078 224 109 11 18 ...
Страница 101: ...PSU 5000 PSG 3000 Maintenance Instructions for Assembly and Operation 1070 078 224 108 13 2 ...
Страница 105: ...PSU 5000 PSG 3000 Instructions for Assembly and Operation Accessories 1070 078 224 108 14 4 ...
Страница 107: ...PSU 5000 PSG 3000 Instructions for Assembly and Operation Storage and transport 1070 078 224 108 15 2 ...
Страница 109: ...PSU 5000 PSG 3000 Instructions for Assembly and Operation Declaration of conformity 1070 078 224 108 16 2 ...
Страница 113: ...PSU 5000 PSG 3000 Instructions for Assembly and Operation Index 1070 078 224 109 17 4 ...
Страница 114: ...1070 078 224 109 98 10 GB MBA AT VWS Printed in Germany ...