![Bosch PSG 3000 Series Скачать руководство пользователя страница 34](http://html.mh-extra.com/html/bosch/psg-3000-series/psg-3000-series_instructions-for-assembly-and-operation-manual_52968034.webp)
PSU 5000 / PSG 3000
Instructions for Assembly and Operation
Technical
data
1070 078 224--108
5--3
5.2 Technical data of the PSG types
5.2.1 Electrical data
PSG
3050.00 A
PSG
3050.10 A
PSG
3075.10 A
PSG
3100.00 A
PSG
3200.00 A
4200 A
see load diagram
page 5--5
connection to
PSU 5100.xxx
connection to
PSU 5100.xxx or
PSU 5200.xxx
(2 x parallel)
connection to
PSU 5200.xxx
5800 A
(with parallel con-
nection to PSU
5200.xxx: 11600 A)
6500 A
see load diagram
page 5--6
see load diagram
page 5--7
see load diagram
page 5--8 and
page 5--10
see load diagram
page 5--9
Transformer
ratio Ü
70
55
50
38
Primary voltage
Continuous direct
current
Nominal direct
voltage
Current--carrying
capacity, depend-
ing on duty cycle
6.3 V
8.4 V
9.0 V
13.0 V
5.2.2 Mechanical data
14 kg
16 kg
25 kg
40 kg
see dimension
drawing sec. 10.2.1
see dimension
drawing sec. 10.2.1
see dimension
drawing sec. 10.2.2
see dimension
drawing sec. 10.2.3
see dimension
drawing sec. 10.2.4
PSG
3050.00 A
PSG
3050.10 A
PSG
3075.10 A
PSG
3100.00 A
PSG
3200.00 A
Weight (approx.)
Connections
mechanical and electrical connections as for standard transformer, series H, M/S EXPERT
5.2.3 Environmental data
PSG
3050.00 A
PSG
3050.10 A
PSG
3075.10 A
PSG
3100.00 A
PSG
3200.00 A
IP 65
When delivered: IP00;
must be covered by terminal box class IP55!
For terminal boxes, see section 14, Accessories
F
!
Cooling
water; 6 l per min.;
max. 30
û
C;
∆
p: max. 0.6 bar
Water connection through G 1/4” internal thread; ”WE”= inlet; ”WA”=outlet ”
water; 10 l per min.;
max. 30
û
C;
∆
p: max. 1 bar
Transformer pro--
tection class
Primary connection
zone protection class
Insulation class
Содержание PSG 3000 Series
Страница 1: ...PSU 5000 PSG 3000 Instructions for Assembly and Operation MF Welding Inverters 109 Version ...
Страница 3: ......
Страница 5: ...PSU 5000 PSG 3000 Instructions for Assembly and Operation 1070 078 224 109 ...
Страница 57: ...PSU 5000 PSG 3000 Monitoring and diagnostics Instructions for Assembly and Operation 1070 078 224 108 7 6 ...
Страница 79: ...PSU 5000 PSG 3000 Installation Cooling Instructions for Assembly and Operation 1070 078 224 108 10 12 ...
Страница 97: ...PSU 5000 PSG 3000 Connection Instructions for Assembly and Operation 1070 078 224 109 11 18 ...
Страница 101: ...PSU 5000 PSG 3000 Maintenance Instructions for Assembly and Operation 1070 078 224 108 13 2 ...
Страница 105: ...PSU 5000 PSG 3000 Instructions for Assembly and Operation Accessories 1070 078 224 108 14 4 ...
Страница 107: ...PSU 5000 PSG 3000 Instructions for Assembly and Operation Storage and transport 1070 078 224 108 15 2 ...
Страница 109: ...PSU 5000 PSG 3000 Instructions for Assembly and Operation Declaration of conformity 1070 078 224 108 16 2 ...
Страница 113: ...PSU 5000 PSG 3000 Instructions for Assembly and Operation Index 1070 078 224 109 17 4 ...
Страница 114: ...1070 078 224 109 98 10 GB MBA AT VWS Printed in Germany ...