EN
| 66
Bosch Security Systems | 2006-05 | V2.0
Dinion IP
| Installation Manual
Alarm recording at
You can select the alarm sensor that is to trigger a recording. You can also use the
motion alarm to trigger the alarm recording.
Note
The alarm sensor must be active to be able to trigger the recording.
The alarm input is activated on the page Alarm sources (see page 67). The
motion alarm is configured and activated on the page Video content
analysis (see page 69).
• Check the box for the alarm sensor that is to trigger a recording. The alarm
sensors selected are indicated by a check mark.
Total partition size
This displays how much storage space the partition occupies on the drive.
Already Used file tracks are displayed in the graphic next to the parameter.
Remaining for recording
This displays the maximum remaining recording time. The value is automatically
updated after the parameters have been modified.
Free space
This displays how much space is still available in the partition.
Used space
This displays how much space is already used in the partition.
Format!
You can delete all recordings in a partition at any time.
Caution
Check the recordings before deleting and back up important sequences on
the computer's hard drive.
• Click the Format! button to delete all recordings in the currently selected
partition.
Содержание NWC?0495
Страница 1: ...Dinion IP NWC 0495 Installation Manual IP Day Night Camera EN ...
Страница 11: ...EN x Bosch Security Systems 2006 05 V2 0 Dinion IP Installation Manual ...
Страница 97: ...EN 96 Bosch Security Systems 2006 05 V2 0 Dinion IP Installation Manual ...
Страница 98: ...Bosch Security Systems 2006 05 Dinion IP Installation Manual ...