EN
| 79
Bosch Security Systems | 2006-05 | V2.0
Dinion IP
| Installation Manual
Multicast address video 1
Enter a valid multicast address for each stream to be operated in multicast mode
(duplication of the data streams in the network). With the setting 0.0.0.0 the
encoder for the relevant stream operates in multi-unicast mode (copying of data
streams in unit). The camera supports multi-unicast connections for up to five
simultaneously connected receivers.
Note
Duplication of data places a heavy demand on the CPU and can lead to
impairment of the image quality under certain circumstances.
Port
If there are simultaneous data streams at the same multicast address, you must
assign different ports to each data stream. Enter the port address for the relevant
stream here.
Streaming
Click in the check box to activate multicast streaming mode for the relevant
stream. An activated stream is marked with a check.
Multicast packet TTL
A value can be entered to specify how long the multicast data packets are active
on the network. If multicast is to be run via a router the value must be greater
than 1.
Version information
The hardware and firmware version numbers are for information only and
cannot be altered. Keep a record of these numbers in case technical assistance is
required.
Hardware version
The hardware version number of the camera is displayed.
Содержание NWC?0495
Страница 1: ...Dinion IP NWC 0495 Installation Manual IP Day Night Camera EN ...
Страница 11: ...EN x Bosch Security Systems 2006 05 V2 0 Dinion IP Installation Manual ...
Страница 97: ...EN 96 Bosch Security Systems 2006 05 V2 0 Dinion IP Installation Manual ...
Страница 98: ...Bosch Security Systems 2006 05 Dinion IP Installation Manual ...