• Use the left or right keys to move through options or to set parameters.
• When in a menu, quickly pressing the menu/select key twice restores the
selected item to its factory default.
• To close all menus at once from any menu, select the
Exit
item and hold down
the menu/select key until the menu display disappears.
Install menu
Install lens wizard submenu
Adjustment procedure DC-iris Lens
1. Unlock the back focus locking button.
2. Access the
Lens Wizard
menu.
3.
Set Back Focus Now
is highlighted in the menu.
4. Turn the back focus adjustment as required.
5. Lock the back focus locking button.
6. Exit the menu.
Function
Selection
Description
Lens Wizard
Select submenu
Select to optimize camera lens combination
Network
Select submenu
Select to set the network IP address for the camera
(default address is 192.168.0.1)
Exit
Exit the menu
Function
Selection
Description
Lens Type
AUTO, MANUAL,
DCIRIS, VIDEO
In AUTO mode the camera auto detects the type of
lens used or force the camera into a mode.
Detected
If the LENS TYPE detection is in AUTO, the
detected lens type is shown.
Set Back
Focus Now
Select to force lens to its maximum opening. After
focusing the lens the object of interest remains in
focus in bright and low light conditions.
Set LVL
(Video iris lenses only). The level detector indicator
must be set to the center by adjusting the level
potentiometer on the lens, to obtain the best picture
performance.
Exit
Return to the INSTALL menu
Содержание NWC?0495
Страница 1: ...Dinion IP NWC 0495 Installation Manual IP Day Night Camera EN ...
Страница 11: ...EN x Bosch Security Systems 2006 05 V2 0 Dinion IP Installation Manual ...
Страница 97: ...EN 96 Bosch Security Systems 2006 05 V2 0 Dinion IP Installation Manual ...
Страница 98: ...Bosch Security Systems 2006 05 Dinion IP Installation Manual ...