MIC Series IP Power Supply
F.01U.265.804 | 1.6 | 2012.08
User Manual
Bosch Security Systems, Inc.
d. Feed your coax cable coming from Bilinx-compatible head-end control system through
the top-left M12 cable gland (item 1,
Figure 3.7
).
e. Attach your coax cable to the other end of the "T" connector.
f. After the PSU is operational, you must access the menu for Encoder settings and
disable the video termination option. See
Section 4.17 Video Input
of the User Manual.
Figure 3.7
Enclosure of MIC IP PSU, with cable glands identified
19.
On non-IR power supplies for non-thermal cameras
: If connecting to additional add-on
cards (for example, a card for 8-input alarms plus washer pump drive (MIC-ALM)),
remove the blanking plug that covers the hole for the bottom-left M12 cable gland (item
3,
Figure 3.7
). Attach the supplied M12 gland. Make the appropriate connections to plug-
in terminal CN2.
20. Through the top right hole (item 2,
Figure 3.7
) of the enclosure, install conduit necessary
to protect standard UTP category 5 cable.
Note:
You may need to remove the cable gland first.
21. Feed the category 5 cable through the conduit and into the enclosure.
22. Connect the RJ45 plug of the cable to the ETH socket on the encoder to connect the
encoder to the network.
Note:
If installing a fiber optic module, see the Fiber Optic Media Converter Installation
Guide for instructions for installing the module in the MIC IP PSU.
Number Description
Cable Gland Size
1
Composite cable (used for analog connections)
1/2 in.
2
RJ45 / Fiber cable
M16
3
For non-thermal cameras: Optional cable gland for alarms
For thermal cameras: optional switched video output
M12
4
Cable gland for optional washer drive
M12