DIVAR 2000/3000
1, 2, 3
,
4
Alarm inputs: max. 4. The alarm becomes active at low voltage. Max.
input voltage 15 VDC.
NO1 C1
,
NO2 C2
,
Two groups of normal open activation outputs (on/off button).
G
Ground cable.
DIVAR 5000
1
,
2
,
3
,
4
,
5
,
6
,
7
,
8
,
9
,
10
,
11
,
12
,
13
,
14
,
15
,
16
Alarm inputs: max. 16. The alarm becomes active at low voltage.
NO1 C1,
NO2 C2,
NO3 C3,
NO4 C4,
NO5 C5
Groups of normal open activation alarm outputs (on/off button).
CTRL +12V
Control power output. Always close the device power to cancel the
alarm.
+12V
External power output. Need the peripheral equipment to provide
+12 V power (below 500 mA).
G
Ground cable.
30
en | Hardware setup
DIVAR 2000 / DIVAR 3000 / DIVAR
5000
2016.09 | v1.0 | AM18-Q0717
Operation Manual
Bosch Security Systems
Содержание DIVAR 2000
Страница 1: ...DIVAR 2000 DIVAR 3000 DIVAR 5000 Network Hybrid Video Recorder en Operation Manual ...
Страница 2: ......
Страница 93: ......