3.
Drag the ‘Sensitivity/Offset’ analog signal source from the Toolbox and drop it on the
desired analog input channel in the DDU 7 Project Tree. A ‘Sensitivity/Offset Wizard’
opens.
4.
To activate the internal pullup-resistor, check the box.
The internal pullup-resistor is used to get a 5 V signal at the analog channel of the DDU 7.
It allows you to use a push-button.
The fixed value of the internal pullup-resistor is 3010 Ohm. If using an additional external
pullup-resistor, set up the overall resistance.
5.
Click ‘Next’ when done.
The second part of the ‘Sensitivity/Offset Wizard’ opens.
Choose unit
group and unit
of physical value
Enter values
from sensor
datasheet
Electrical
(pin) value
Physical
(channel)
value
6.
Click ‘Next’ when done. The third part of the ‘Sensitivity/Offset Wizard’ opens.