14.3
Lap timing
There are different possibilities to adjust the lap trigger to the timing situation.
The detection time defines the minimum time the input signal changes its state. E.g. a low
active signal needs to be below the threshold for min. 15 ms to release the trigger.
Channels for display
To display lap times use the following channels:
Channel
Function
Laptrigger_lapctr_dls
Number of completed laps
Laptrigger_laptime_dls
Running laptime
Laptrigger_laptime_best_dls
Laptime of best lap
Laptrigger_laptimeold_dls
Laptime of last lap completed
Laptrigger_laptimeseg_dls
Segment time of last segment
Laptrigger_lapctr_dls
Number of completed laps
14.3.1
Time Based Retrigger Protection
Trigger is locked for 5 s after main trigger was received.
To deactivate time based retrigger protection, set ‘Retrigger lock time’ to 0 ms.
5000ms
Main Trigger
14.3.2
Distance Based Retrigger Protection
Trigger is locked until 80% of track distance has been covered (3,200 m).