62
en | Display Configuration
Display Unit DDU 7
04.02.2019 | V 02 |
Manual
Bosch Motorsport
2
nd
: Click on the
dropdown arrow
beside ‘Add
condition’
3
rd
: Choose
‘Conditional
combination’
1
st
: Double-
click on
‘Conditional
Channels’ in
Project Tree
The ‚create/edit condition combination‘ window appears.
Create/Edit Condition Window
1.
Define the condition combination using the following configuration possibilities:
a) Enter the name of the condition combination.
b) Create the condition combination in the window.
Choose a channel (condition, conditional function, math, measurement channel with
binary values) to be compared.
Combine multiple conditions by adding ‘AND’ or ‘OR’ relations.
To negate a condition, right-click on the condition and select ‘Negation (!)’.
Combine several (up to 16) conditions.
2.
Click ‘Next’ to got to the next page.
Choose the output setting of the result.
Constant TRUE/FALSE: Result is as a constant with the value TRUE or FALSE.
Blinking: Result is a blinking if the condition is fulfilled.
Pulse: Result is a short one-time pulse if the condition is fulfilled.
Toggling output: Result is a pulse that lasts until the next condition is fulfilled.
3.
Click ‘Finish’ when done.
Содержание DDU 7
Страница 1: ...Display Unit DDU 7 Manual V 02 2 4 2019 ...
Страница 2: ......
Страница 16: ...16 en Mechanical Drawing Display Unit DDU 7 04 02 2019 V 02 Manual Bosch Motorsport 6 Mechanical Drawing ...
Страница 139: ...Display Unit DDU 7 Firmware en 139 Bosch Motorsport Manual 04 02 2019 V 02 ...
Страница 141: ...Display Unit DDU 7 Clone the Unit en 141 Bosch Motorsport Manual 04 02 2019 V 02 Upgrade features ...
Страница 155: ......